2021
DOI: 10.1016/j.proci.2020.06.086
|View full text |Cite
|
Sign up to set email alerts
|

On the primary thermal decomposition pathways of hydroxycinnamic acids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 27 publications
1
11
0
Order By: Relevance
“…Crystalline LH showed its melting point around 260 °C, followed by a small thermal degradation peak (Figure a), which was the same as with our previous report . We found the fusion endotherms of pHCA and CA were 222.8 and 134.3 °C, respectively (Figure b,c), which were consistent with the reported results. , Moreover, it was observed that the physical mixtures of LH and CA exhibited two endothermic peaks, similar to their melting points (Figure S2a–c). However, the physical mixtures of LH and pHCA showed only one melting endotherm in the temperature range of 174–177 °C (Figure S2d–f), probably suggesting that a low eutectic mixture was formed between LH and pHCA.…”
Section: Resultssupporting
confidence: 91%
“…Crystalline LH showed its melting point around 260 °C, followed by a small thermal degradation peak (Figure a), which was the same as with our previous report . We found the fusion endotherms of pHCA and CA were 222.8 and 134.3 °C, respectively (Figure b,c), which were consistent with the reported results. , Moreover, it was observed that the physical mixtures of LH and CA exhibited two endothermic peaks, similar to their melting points (Figure S2a–c). However, the physical mixtures of LH and pHCA showed only one melting endotherm in the temperature range of 174–177 °C (Figure S2d–f), probably suggesting that a low eutectic mixture was formed between LH and pHCA.…”
Section: Resultssupporting
confidence: 91%
“…The pyrolysis experiments were performed in a micropyrolysis unit consisting of two sections, viz., reactor and analytics (Figure a) . The reactor is a double-shot tandem micropyrolyzer (Frontier Laboratories, Japan) with two reactors connected in series.…”
Section: Methodsmentioning
confidence: 99%
“…The pyrolysis experiments were performed in a micropyrolysis unit consisting of two sections, viz., reactor and analytics (Figure 2a). 48 The reactor is a double-shot tandem micropyrolyzer (Frontier Laboratories, Japan) with two reactors connected in series. In this study, only the first reactor with a deactivated quartz tube was used to study liquid or solid to gas transformations of hydroxycinnamaldehydes under pyrolysis con-ditions (at 773−1123 K and 2.8 atm).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…As described previously, the experiments were performed with a double-shot tandem micropyrolyzer. 31 Only the first reactor was used in this work. It is directly connected to the GC inlet to perform solid-to-gas experiments in this study.…”
Section: Micropyrolyzer Unitmentioning
confidence: 99%