2021
DOI: 10.3390/nano11081892
|View full text |Cite
|
Sign up to set email alerts
|

One-Step Electrodeposition Synthesized Aunps/Mxene/ERGO for Selectivity Nitrite Sensing

Abstract: In this paper, a new nanocomposite AuNPs/MXene/ERGO was prepared for sensitive electrochemical detection of nitrite. The nanocomposite was prepared by a facile one-step electrodeposition, HAuCl4, GO and MXene mixed in PBS solution with the applied potential of –1.4 V for 600 s. The modified material was characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) and cyclic voltammetry (CV). The electrochemical behavior of nitrite at the modified elec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 57 publications
(46 reference statements)
0
10
0
Order By: Relevance
“…However, because of the occupancy of—and decrease in the number of—active sites at higher analyte concentrations, the sensitivity and the slope became lower [ 44 ]. This demonstrates that the quantitative analysis of CBD using the Fe 3 O 4 -NH 2 -GN/GCE was interesting and acceptable [ 45 ]. The detection abilities of the reported electrochemical sensors for CBD are listed and compared with the Fe 3 O 4 -NH 2 -GN/GCE in Table 2 .…”
Section: Resultsmentioning
confidence: 99%
“…However, because of the occupancy of—and decrease in the number of—active sites at higher analyte concentrations, the sensitivity and the slope became lower [ 44 ]. This demonstrates that the quantitative analysis of CBD using the Fe 3 O 4 -NH 2 -GN/GCE was interesting and acceptable [ 45 ]. The detection abilities of the reported electrochemical sensors for CBD are listed and compared with the Fe 3 O 4 -NH 2 -GN/GCE in Table 2 .…”
Section: Resultsmentioning
confidence: 99%
“…The MXene powder was prepared by our last work [ 29 ]. A measure of 0.4 g CS powder was added into 1 mL Acetic acid and then added ultrapure water until 100 g, and was stirred for 2 h to obtain CS solution (0.4 wt%, pH = 4.05).…”
Section: Methodsmentioning
confidence: 99%
“…The resulted electrode AuNPs/Chit/Ti 3 C 2 T x /GCE showed good performance, two linear ranges, 0.5–335 μM and 335–3355 μM, and LOD of 0.069 μM. In their previous research [ 18 ], a AuNPs/Ti 3 C 2 T x /ERGO/GCE sensor was designed exhibiting linear ranges 0.5–80 μM and 80–780 μM with limits of detection 0.15 μM and 0.051 μM for nitrites sensing.…”
Section: Introductionmentioning
confidence: 94%