2015
DOI: 10.1016/j.chroma.2015.09.051
|View full text |Cite
|
Sign up to set email alerts
|

Online post-column solvent assisted and direct solvent-assisted electrospray ionization for chiral analysis of propranolol enantiomers in plasma samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 21 publications
0
16
0
Order By: Relevance
“…These phenomena can be interpreted as follows: when HCOOH was increased, sufficient ionized H + species were generated to react with LiCoO 2 powder in the solid/liquid interphase, and when the interfacial H + concentration was reduced, the additional ionized H + species could diffuse outward. [23][24][25] Fig. 2 shows that the theoretical LiCoO 2 /HCOOH reactive ratio was 1 : 3.…”
Section: Leaching Of Licoo 2 With Hcoohmentioning
confidence: 94%
“…These phenomena can be interpreted as follows: when HCOOH was increased, sufficient ionized H + species were generated to react with LiCoO 2 powder in the solid/liquid interphase, and when the interfacial H + concentration was reduced, the additional ionized H + species could diffuse outward. [23][24][25] Fig. 2 shows that the theoretical LiCoO 2 /HCOOH reactive ratio was 1 : 3.…”
Section: Leaching Of Licoo 2 With Hcoohmentioning
confidence: 94%
“…The optimal composition resulted in a 30‐fold increase in signal on average. Elmongy et al showed that by post‐column addition of 0.5% formic acid in isopropanol to a normal‐phase chromatography flow the signal‐to‐noise ratio was improved by more than 40‐fold. Carabias‐Martinez et al reported up to 200 times increase in signal‐to‐noise ratio with post‐column base addition in negative ionization mode.…”
Section: Introductionmentioning
confidence: 99%
“…The optimal composition resulted in a 30-fold increase in signal on average. Elmongy et al 14 showed that by post-column addition of 0.5% formic acid in isopropanol to a normal-phase chromatography flow the signal-to-noise ratio was improved by more than 40-fold. Merck (Darmstadt, Germany).…”
Section: Introductionmentioning
confidence: 99%
“…SAESI‐MS allows timesaving, no heating and less solvent consumption. Several applications of various nonpolar or low‐polarity solvent systems have been demonstrated by SAESI‐MS …”
Section: Introductionmentioning
confidence: 99%
“…When the sample is a liquid, continuous injection, continuous monitoring and continuous analysis are often necessary, and an analytical strategy based on the atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) mass spectrometry mechanism is appropriate. However, nonpolar or low-polarity solvents extracts, such as petroleum ether extracts, are difficult to analyze applications of various nonpolar or low-polarity solvent systems have been demonstrated by SAESI-MS. 22,[24][25][26] In the study reported here we attempted to perform the direct…”
Section: Introductionmentioning
confidence: 99%