1992
DOI: 10.1016/0168-1176(92)80006-m
|View full text |Cite
|
Sign up to set email alerts
|

Open trapped ion cell geometries for Fourier transform ion cyclotron resonance mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
74
0

Year Published

1996
1996
2011
2011

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(74 citation statements)
references
References 26 publications
0
74
0
Order By: Relevance
“…fused silica capillary, which had been mechanically ground to a uniform thin-walled tip [20]. The electrosprayed ions were transported into the mass spectrometer through a Chait-style atmosphere-to-vacuum interface [21] and externally accumulated [22] [23] cylindrical cell. The ions were subjected to chirp excitation (72 to 320 kHz at 150 Hz/ s) and direct-mode broadband detection (1 Mword data points).…”
Section: Esi-fticr-msmentioning
confidence: 99%
“…fused silica capillary, which had been mechanically ground to a uniform thin-walled tip [20]. The electrosprayed ions were transported into the mass spectrometer through a Chait-style atmosphere-to-vacuum interface [21] and externally accumulated [22] [23] cylindrical cell. The ions were subjected to chirp excitation (72 to 320 kHz at 150 Hz/ s) and direct-mode broadband detection (1 Mword data points).…”
Section: Esi-fticr-msmentioning
confidence: 99%
“…A 20 min delay time between the start of the LC method and the start of the spot deposition was used. 21 cylindrical open ICR cell. 22,23 Ions were excited by broadband frequency chirp excitation and detected before a single zero-fill, Gaussian apodization, and Fourier transform.…”
Section: Methodsmentioning
confidence: 99%
“…We have recently demonstrated the feasibility of targeted MS/MS based on the abundance ratios (ARs) of 14 N/ 15 N-labeled peptide pairs using an LC-FTICR platform [6]. In a tryptic peptide mixture of Shewanella oneidensis proteins, we were able to specifically target and identify species that were differentially abundant in suboxic versus aerobic conditions; for several identified proteins, differential abundance was confirmed by alternative techniques [7].…”
mentioning
confidence: 96%
“…Briefly, the mass spectrometer incorporates an ESI source (with the chemically etched tip° [12]),°a°heated°capillary°(160°°C),°an°electrodynamic ion°funnel° [13],°a°collisional°quadrupole°for°ion°focusing (Q 0 ), two selection quadrupoles (Q 1 and Q 2 ), an accumulation quadrupole (Q 3 ), and a transfer quadrupole (Q 4 )°that°leads°to°an°open°cylindrical°ICR°trap° [14].°Q 1 is an RF-only quadrupole with notch ejection capability, which offers "dynamic range expansion applied to mass°spectrometry"°(DREAMS)°capability° [15,°16],°but was used only as an ion guide in this study. Q 2 is a commercial quadrupole mass filter (6 mm rod diameter, Extrel) powered by a commercial RF power supply (150-QC, Extrel, Pittsburgh, PA) working at 880 kHz.…”
Section: Fticr Msmentioning
confidence: 99%