2022
DOI: 10.3389/fnins.2022.779048
|View full text |Cite|
|
Sign up to set email alerts
|

OPRA-RS: A Hearing-Aid Fitting Method Based on Automatic Speech Recognition and Random Search

Abstract: Hearing-aid (HA) prescription rules (such as NAL-NL2, DSL-v5, and CAM2) are used by HA audiologists to define initial HA settings (e.g., insertion gains, IGs) for patients. This initial fitting is later individually adjusted for each patient to improve clinical outcomes in terms of speech intelligibility and listening comfort. During this fine-tuning stage, speech-intelligibility tests are often carried out with the patient to assess the benefits associated with different HA settings. As these tests tend to be… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(13 citation statements)
references
References 21 publications
0
13
0
Order By: Relevance
“…The present study extends the work of Gonçalves Braz et al (2022) by investigating whether OPRA-RS can also be used to optimize time constants. Attack and release times were optimized for HA configurations that corresponded to the compression thresholds and/or the insertion gains recommended either by OPRA-RS or by CAM2 for the same 12 audiometric profiles as used in Gonçalves Braz et al (2022) .…”
Section: Introductionmentioning
confidence: 64%
See 4 more Smart Citations
“…The present study extends the work of Gonçalves Braz et al (2022) by investigating whether OPRA-RS can also be used to optimize time constants. Attack and release times were optimized for HA configurations that corresponded to the compression thresholds and/or the insertion gains recommended either by OPRA-RS or by CAM2 for the same 12 audiometric profiles as used in Gonçalves Braz et al (2022) .…”
Section: Introductionmentioning
confidence: 64%
“…The present study extends the work of Gonçalves Braz et al (2022) by investigating whether OPRA-RS can also be used to optimize time constants. Attack and release times were optimized for HA configurations that corresponded to the compression thresholds and/or the insertion gains recommended either by OPRA-RS or by CAM2 for the same 12 audiometric profiles as used in Gonçalves Braz et al (2022) . As these HA configurations sometimes involved high compression ratios (>3), and that in such cases, fast compression can distort the signal envelope and thus affect speech intelligibility ( Souza, 2002 ), only “slow” compression speeds were used.…”
Section: Introductionmentioning
confidence: 64%
See 3 more Smart Citations