2020
DOI: 10.1007/s12028-020-00970-y
|View full text |Cite
|
Sign up to set email alerts
|

Optic Nerve Sheath Diameter is not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0
5

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(38 citation statements)
references
References 29 publications
0
33
0
5
Order By: Relevance
“…11) However, in contrast, recent studies have reported that the ONSD may not reflect IICP in patients with aneurysmal SAH. 18) Bauerle et al reported that 27 patients with acute aneurysmal SAH did not show any correlations between ONSD by US and IICP. 2) In a study of 20 patients with aneurysmal SAH by Zoerle et al, ONSD measurements using US were related poorly to the ICP measured directly and simultaneously through ventricular catheters.…”
Section: A B C Dmentioning
confidence: 96%
“…11) However, in contrast, recent studies have reported that the ONSD may not reflect IICP in patients with aneurysmal SAH. 18) Bauerle et al reported that 27 patients with acute aneurysmal SAH did not show any correlations between ONSD by US and IICP. 2) In a study of 20 patients with aneurysmal SAH by Zoerle et al, ONSD measurements using US were related poorly to the ICP measured directly and simultaneously through ventricular catheters.…”
Section: A B C Dmentioning
confidence: 96%
“…For example, in Rajajee et al, they found that using the 5.9 mm cutoff reported in Geeraerts et al would have missed 81% of the high ICP measurements using their study population. Additionally, a study investigating the relationship between ONSD and ICP measured via EVD in 20 SAH patients did not find any detectable relationship [105]. Further, in 10 of the patients, changes in ONSD were monitored during fairly rapid ICP change after controlled CSF drainage.…”
Section: Optic Nerve Sheath Diametermentioning
confidence: 96%
“…Further, in 10 of the patients, changes in ONSD were monitored during fairly rapid ICP change after controlled CSF drainage. Only two patients displayed agreement between the profiles of ICP and ONSD in both eyes, while four showed agreement in one eye, and the remainder showed no agreement, leading the authors to conclude that ONSD measurements can not be used to accurately estimate ICP in SAH patients [105].…”
Section: Optic Nerve Sheath Diametermentioning
confidence: 99%
See 1 more Smart Citation
“…Fast alle Studien belegen die signifikante Korrelation bei akuten Drucksteigerungen [12,25,26,30]. Erwartungsgemäß ist auf eine teilweise fehlende Korrelation zwischen ONSD und ICP nach Liquordrainage bei SAB-Patienten hingewiesen worden [31], s.u.…”
Section: Prognose Und Indikationsstellungunclassified