2015
DOI: 10.1117/12.2178594
|View full text |Cite
|
Sign up to set email alerts
|

Optical sensors based on the molecular condensation nuclei detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
2
2

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…where k -the wavenumber, R -the distance from the observation point to the center of the sphere, 1 S and 2 S -the elements of the amplitude scattering matrix, the index i -denotes the incident wave and s -the scattered wave. If the incident light is not polarized then the intensity of the scattered light is given by where n a , n b -the scattered field coefficients (Mie coefficients), n π n τ -the angular scattering coefficients.…”
Section: Light Scattering By Aerosol Particles In Condensation Nucleimentioning
confidence: 99%
See 2 more Smart Citations
“…where k -the wavenumber, R -the distance from the observation point to the center of the sphere, 1 S and 2 S -the elements of the amplitude scattering matrix, the index i -denotes the incident wave and s -the scattered wave. If the incident light is not polarized then the intensity of the scattered light is given by where n a , n b -the scattered field coefficients (Mie coefficients), n π n τ -the angular scattering coefficients.…”
Section: Light Scattering By Aerosol Particles In Condensation Nucleimentioning
confidence: 99%
“…The basic design of the photometer of a CND has been presented in 8 . The photometer is of a nephelometric type, i.e.…”
Section: Light Scattering By Aerosol Particles In Condensation Nucleimentioning
confidence: 99%
See 1 more Smart Citation
“…To calculate the threshold sensitivity for various PMT anode voltages the corresponding values of S A , μ and I DA from the technical specifications of a PMT must be substituted into (11). Calculations made for the threshold sensitivity of a photointegrator with an H6780 PMT (manufactured by Hamamatsu, Japan) and a 1 s integration time gave the best sensitivity of P 0_FMP = 0.48 · 10 −15 W at the anode voltage of 700 V. Therefore, the gain in sensitivity achieved by using a PMT instead of a photodiode was 18-30 times.…”
Section: Threshold Sensitivity Of Photomultiplier Tube (Pmt)-based Phmentioning
confidence: 99%
“…This in turn allowed the development of highly sensitive MCN gas analyzers for the detection of various pollutants [2]. They include mass-produced poisonous gas detectors "Kaskad-G" and "Kaskad-5" [10], experimental detectors of metal carbonyls and explosives, medical breath analyzers [11], leakage detector for heat exchangers of nuclear reactors, gas mask testers [1].…”
Section: Introductionmentioning
confidence: 99%