2022
DOI: 10.1109/access.2022.3153042
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Allocation of Renewable Distributed Generations Using Heuristic Methods to Minimize Annual Energy Losses and Voltage Deviation Index

Abstract: In this paper, two metaheuristic methods, genetic algorithm and particle swarm optimization, are proposed to determine the optimal locations, sizes and power factors of single and double distributed generation units. In line with the 2050 carbon neutral goal, the aim was to integrate renewable distributed energy sources such as photovoltaic panels and wind turbines into the distribution system with a high penetration level. In contrast to most studies based on constant loads and dispatchable generations, an ap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 91 publications
(34 citation statements)
references
References 56 publications
(68 reference statements)
0
34
0
Order By: Relevance
“…To improve the network performance, the voltage deviations should be kept closed to 1 p.u. value which can be defined as 36,39 italicVD=h=124k=1NB|(Vk1)|, $\sum {VD}=\sum _{h=1}^{24}\sum _{k=1}^{{NB}}|({V}_{k}-1)|,$where italicNB ${NB}$ represents the number of buses in the network, and Vk ${V}_{k}$ represents the voltage of the k th bus.…”
Section: Problem Formulationmentioning
confidence: 99%
“…To improve the network performance, the voltage deviations should be kept closed to 1 p.u. value which can be defined as 36,39 italicVD=h=124k=1NB|(Vk1)|, $\sum {VD}=\sum _{h=1}^{24}\sum _{k=1}^{{NB}}|({V}_{k}-1)|,$where italicNB ${NB}$ represents the number of buses in the network, and Vk ${V}_{k}$ represents the voltage of the k th bus.…”
Section: Problem Formulationmentioning
confidence: 99%
“…The amplitude of bus voltage should be limited by the minimum and maximum limits that satisfy the following constrain (7):…”
Section: • Voltage Bus Limitmentioning
confidence: 99%
“…For these reasons, installing RESs has a significant impact on the distribution system performance since their optimal placement decreases power system's losses and enhances the voltage profile 7,8 . However, there are uncertainties associated, such as load variations and the random nature of RES 9,10 which substantially influences the optimization problem's data and solutions.…”
Section: Introductionmentioning
confidence: 99%
“…With growing global fears about the depletion of fossil fuels, including the environmental consequences of their use, the adoption of Distributed Generation (DG) has been portrayed as the ideal solution 1 . Notably, the spread of DG has contributed numerous avails to the electrical system, the environment, and consumers 2 , 3 . Besides, the cost of losses in the electrical network raises consumers’ bills.…”
Section: Introductionmentioning