41st North American Power Symposium 2009
DOI: 10.1109/naps.2009.5484002
|View full text |Cite
|
Sign up to set email alerts
|

Optimal PMU placement for fault location in a power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
30
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 25 publications
(30 citation statements)
references
References 6 publications
0
30
0
Order By: Relevance
“…The purpose of PMU placement optimization is to accomplish complete fault observability with the minimum number of PMUs. A line is fault observable if the voltage at the two ends of the line and the current at only one end of the line are known . The PMU placement problem can be defined and solved using the binary integral linear programming technique as follows: min.0.25emf=truetruefalse∑i=1Nwixi such that0.25em0.25emlines(),ij0.25em,0.25emFi,j:0.25emxi+xj1 x is a binary decision variable vector, defined as xi= {center1if0.25emnormala0.25emnormalPnormalMnormalU0.25emis installed0.25emnormalat0.25embus0.37emicenter0otherwise w i is the cost of the PMU located at bus i .…”
Section: Methodsmentioning
confidence: 99%
“…The purpose of PMU placement optimization is to accomplish complete fault observability with the minimum number of PMUs. A line is fault observable if the voltage at the two ends of the line and the current at only one end of the line are known . The PMU placement problem can be defined and solved using the binary integral linear programming technique as follows: min.0.25emf=truetruefalse∑i=1Nwixi such that0.25em0.25emlines(),ij0.25em,0.25emFi,j:0.25emxi+xj1 x is a binary decision variable vector, defined as xi= {center1if0.25emnormala0.25emnormalPnormalMnormalU0.25emis installed0.25emnormalat0.25embus0.37emicenter0otherwise w i is the cost of the PMU located at bus i .…”
Section: Methodsmentioning
confidence: 99%
“…Optimal placement of phasor measurement units (PMUs) for fault observability is studied in , . The author of formulates an optimization problem so that fault location can be performed using the bus impedance matrix and by only voltage measurements, which can be distant from the fault line.…”
Section: Introductionmentioning
confidence: 99%
“…The author of formulates an optimization problem so that fault location can be performed using the bus impedance matrix and by only voltage measurements, which can be distant from the fault line. Other methods for fault‐location observability separate the entire network into smaller sub networks and ensure the possibility of accurate two‐ or multi‐ended fault location for each of them. However, these methods may not lead to the minimum number of PMUs.…”
Section: Introductionmentioning
confidence: 99%