2020
DOI: 10.18662/brain/11.4sup1/158
|View full text |Cite
|
Sign up to set email alerts
|

Optimising the Validity of Shoulder Range of Motion Evaluation: A Comparative Study

Abstract: During the assessment process diachronically conceived in the initial, dynamic, and final stages, data recording is often performed by instrumental measurement using the goniometer. In Romania, the logistics equipment - hardware and software - has a very low or even absent incidence in the conceptual and applicative design of kinetic rehabilitation programmes. Some disadvantages of universal goniometry are revealed by relatively accurate measurements, given that the testing instrument may provide erroneous dat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…To measure the range of motion using a goniometer, the universal axis of motion was marked on the prominence of the humerus head, and the axis of the goniometer was placed on it. The fixed arm was placed parallel to the participant's body, and the movable arm was placed in the middle of the midline of the arm at the end of the movement, and the number read was recorded [17].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…To measure the range of motion using a goniometer, the universal axis of motion was marked on the prominence of the humerus head, and the axis of the goniometer was placed on it. The fixed arm was placed parallel to the participant's body, and the movable arm was placed in the middle of the midline of the arm at the end of the movement, and the number read was recorded [17].…”
Section: Methodsmentioning
confidence: 99%
“…The movable arm was placed when the participant raised their arm and the midline of the arm was in line with the midline of the movable arm of the goniometer. The range of motion was recorded [17].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In a previous study, we showed lower inter-tester differences and statistically significant improvements in the error rate, when the Kinesimeter was used for assessing the shoulder’s range of motion, compared to the classical goniometer [ 39 ]. From these results, we have concluded that our device is a valid and reliable instrument to measure the precise angles and degrees of the shoulder joint.…”
Section: Methodsmentioning
confidence: 99%