1976
DOI: 10.1021/ac60370a026
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of arsine generation in atomic absorption arsenic determinations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
19
0
1

Year Published

1977
1977
2012
2012

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(21 citation statements)
references
References 13 publications
1
19
0
1
Order By: Relevance
“…The effect of oxygen on the atomization of As and Sb hydrides in the heated quartz tubes was first reported by Gouldden et al 164 They reported that an increase in the sensitivity could be obtained if oxygen was added to the purge gas. Similarly, Siemer et al 172 based on their studies on the optimization of arsine generation in flame-in quartz tube atomizers, found that the sensitivity could be increased by using hydrogen for stripping the arsine, rather than using argon or nitrogen. According to Siemer et al, 172 carrier gases like Ar and N2 dilute the analyte atoms within the atomizer, but no reason was given for the observed sensitivity increase.…”
Section: ·3 Free Radical Mechanismmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect of oxygen on the atomization of As and Sb hydrides in the heated quartz tubes was first reported by Gouldden et al 164 They reported that an increase in the sensitivity could be obtained if oxygen was added to the purge gas. Similarly, Siemer et al 172 based on their studies on the optimization of arsine generation in flame-in quartz tube atomizers, found that the sensitivity could be increased by using hydrogen for stripping the arsine, rather than using argon or nitrogen. According to Siemer et al, 172 carrier gases like Ar and N2 dilute the analyte atoms within the atomizer, but no reason was given for the observed sensitivity increase.…”
Section: ·3 Free Radical Mechanismmentioning
confidence: 99%
“…Similarly, Siemer et al 172 based on their studies on the optimization of arsine generation in flame-in quartz tube atomizers, found that the sensitivity could be increased by using hydrogen for stripping the arsine, rather than using argon or nitrogen. According to Siemer et al, 172 carrier gases like Ar and N2 dilute the analyte atoms within the atomizer, but no reason was given for the observed sensitivity increase.…”
Section: ·3 Free Radical Mechanismmentioning
confidence: 99%
“…A atomização do hidreto dá-se nesta chama interna. Este sistema foi descrito pela primeira vez por Siemer 56 e seu modelo, combinado com chama oxigênio-hidrogênio 57 ou ar-hidrogênio 58 , foi adotado por outros autores, sem ou com algumas modificações 53,57,[59][60][61][62][63][64][65][66] . Matousek et al 67,68 propuseram um tubo de quartzo com micro-chama múltipla para a determinação de As, Se e Sb.…”
Section: Atomização Em Tubo Com Chama Internaunclassified
“…Therefore, arsenic can be more readily accumulated into hair and nail than other tissues. 2 Some analytical methods have been used for trace determination of arsenic such as: Colorimetry, 3,4 Atomic Absorption Spectrometry, 4,5 hydride generation system combined with Atomic Absorption Spectrometry, 6 inductively coupled plasma mass spectrometry. 7,8 and Atomic Fluorescence Spectrometry.…”
Section: Introductionmentioning
confidence: 99%