2013
DOI: 10.4236/ajac.2013.46039
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Chromium (Vi) Removal by Donnan Dialysis

Abstract: The removal of chromium (VI) from aqueous solutions by Donnan dialysis has been investigated in this paper. In this process, two anion-exchange membranes (AEMs) were used: Selemion ® AMV and Neosepta ® AFN. The amount of chromium (VI) removed was determined in terms of the following parameters: initial concentration of chromium (VI), type of anion-exchange membrane, concentration of counter-ion and magnetic stirring rate. A 24 full factorial design analysis was performed to screen the parameters affecting the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2013
2013
2025
2025

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 41 publications
0
13
0
Order By: Relevance
“…This mixture improved the Cr(III) transport relative to using HNO 3 alone. The high sodium ion concentration in the extractor mixture may exchange with the Cr(III) ions and stimulates both ion diffusion due to the concentration gradient . The percent extraction membrane were ordered as MplasmaNa [49.36%; see Figure (D) a] > M414%PNa [41.14%; see Figure (D) b] > M416%0Na(32.66%) > M432%0Na (29.43%) > MPP (11.23%).…”
Section: Resultsmentioning
confidence: 99%
“…This mixture improved the Cr(III) transport relative to using HNO 3 alone. The high sodium ion concentration in the extractor mixture may exchange with the Cr(III) ions and stimulates both ion diffusion due to the concentration gradient . The percent extraction membrane were ordered as MplasmaNa [49.36%; see Figure (D) a] > M414%PNa [41.14%; see Figure (D) b] > M416%0Na(32.66%) > M432%0Na (29.43%) > MPP (11.23%).…”
Section: Resultsmentioning
confidence: 99%
“…This mixture did not improve the Cr(III) transport relative to using HNO 3 alone at pH 3.0. The high sodium ion concentration in the extractor mixture may exchange with the Cr(III) ions and stimulate ion diffusion due to the concentration gradient 61,62 , but this exchange did not occur.…”
Section: Thermogravimetric(tga)analysismentioning
confidence: 99%
“…The low pH in the extractor solution may exchange with the Cr(III) ions more rapidly and stimulates diffusion of both ions due to the concentration gradient 61,62 . However, the mass transport coefficient is higher in the pH 3.0 extractor solution than in the pH 1.0 extractor solution.…”
Section: Thermogravimetric(tga)analysismentioning
confidence: 99%
“…The study allowed us to find the best conditions to remove the chromium (VI) by Donnan dialysis. These conditions were obtained in previous study ([Cr (VI) = 100 mg·L ; AFN and high speed of magnetic stirring) and will be used for this study in order to improve the efficiency of this process for the removal of chromium [44].…”
Section: Donnan Dialysismentioning
confidence: 99%