1992
DOI: 10.1016/0021-9673(92)87147-z
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of detection sensitivity in the analysis of inorganic cations by capillary ion electrophoresis using indirect photometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
20
0

Year Published

1997
1997
2012
2012

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 75 publications
(21 citation statements)
references
References 18 publications
1
20
0
Order By: Relevance
“…As summarized in Table I, the K ass increased in the order of Li + ≈ Na + < NH 4 + ≈ K + << Sr 2+ < Ca 2+ < Mg 2+ in PFOSA, NH 4 + ≈ K + < Na + < Li + < Sr 2+ < Ca 2+ < Mg 2+ in Brij35 and C12N3S, and Li + < NH 4 + ≈ K + < Na + << Sr 2+ < Ca 2+ < Mg 2+ in DPC. It should be noted that the K ass values of divalent cations observed for PFOSA were larger those for Brij35, C12N3S, and DPC.…”
Section: Determination Of Association Constant Of Inorganic Cations Tmentioning
confidence: 93%
See 2 more Smart Citations
“…As summarized in Table I, the K ass increased in the order of Li + ≈ Na + < NH 4 + ≈ K + << Sr 2+ < Ca 2+ < Mg 2+ in PFOSA, NH 4 + ≈ K + < Na + < Li + < Sr 2+ < Ca 2+ < Mg 2+ in Brij35 and C12N3S, and Li + < NH 4 + ≈ K + < Na + << Sr 2+ < Ca 2+ < Mg 2+ in DPC. It should be noted that the K ass values of divalent cations observed for PFOSA were larger those for Brij35, C12N3S, and DPC.…”
Section: Determination Of Association Constant Of Inorganic Cations Tmentioning
confidence: 93%
“…In cation separations by CE, Hjertén first reported for the separation of Bi 3+ and Cu 2+ with lactic acid as complexing agent [3]. From this work, many papers have been published on the analysis of alkali and alkaline earth metals, and ammonium ion [4][5][6] in the early 1990s.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Because of its speed, resolving power, minimal sample and reagent requirements, greater simplicity in operation compared to IC and adaptability to a variety of applications using different separation conditions, it has been applied extensively to many analytes in a variety of areas. Many papers were published on the analysis of alkali, alkaline earth and NH 4 + [2][3][4][5] in the early 1990s. Crown ethers have been applied to CE to improve the separation of K + and NH 4 + [3,5].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, an indirect UV absorption technique, in which the analyte displaces a mobile phase additive in the eluted band, has been used successfully in capillary electrophoresis. [7][8][9][10][11][12][13] The displacement causes a decrease in the absorption or fluorescence signal, because the concentration of the mobile-phase additive is lower in the eluted bands when compared with its steady-state concentration.…”
mentioning