2021
DOI: 10.1016/j.egyr.2021.08.106
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of influential geometrical parameters of single slope solar still equipped with thermoelectric system to achieve maximum desalinated water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…They found that the module was the main contributor to the exergy destruction, with the glass cover having the least effect. Esfe et al [ 219 ] performed simulations to demonstrate that thermoelectric cooling uplifts WP by 7% in comparison with without cooling. Nazari et al [ 220 ] experimented using solar still with an external thermoelectric condensation channel and found that the placement of four cooling modules around the channel walls increased still productivity by about 39%.…”
Section: Enhancing Desalination Via Condensationmentioning
confidence: 99%
“…They found that the module was the main contributor to the exergy destruction, with the glass cover having the least effect. Esfe et al [ 219 ] performed simulations to demonstrate that thermoelectric cooling uplifts WP by 7% in comparison with without cooling. Nazari et al [ 220 ] experimented using solar still with an external thermoelectric condensation channel and found that the placement of four cooling modules around the channel walls increased still productivity by about 39%.…”
Section: Enhancing Desalination Via Condensationmentioning
confidence: 99%
“…Esfe et al 21 added a fan with a heat sink in a conventional solar still with a length of 0.438 m, a large height of 0.187 m, and a small height of 0.075 m. The mounting angle of the glass was taken as 30°. The left‐ and right‐side walls were taken as adiabatic and zero flux condition was considered.…”
Section: Enhancing Performance Of Solar Stillsmentioning
confidence: 99%
“…Esfe et al21 added a fan with a heat sink in a conventional solar still with a length of 0.438 m, a large height of 0.187 m, and a small height F I G U R E 5 Velocity contours (a) CFD simulation, (b) experiment 18. of 0.075 m. The mounting angle of the glass was taken as 30 .…”
mentioning
confidence: 99%
“…The merits of thermoelectric (TE) are that it does not have any moving parts, compact, eco-friendly, has no chemical reaction, wide operating temperature range, maintenance-free, and has a long life span [7]. Various studies have also been performed to improve the heat transfer in heat exchangers [8][9][10][11][12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%