2020
DOI: 10.1007/s11694-020-00531-z
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of process parameters of osmotic pressure treatment and heat moisture treatment for rice starch using response surface methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 44 publications
0
2
0
Order By: Relevance
“…The increase in SOL also occurred in OPT-modified starch, which was in line with another study on OPT corn starch [18] and on OPT breadfruit starch [12]. OPT can inhibit starch gelatinization and swelling [44]. Furthermore, Pukkahuta et al [45] showed that a decrease in swelling of OPT was caused by a decrease in enthalpy of gelatinization, which increased the amorphous region of the starch granules.…”
Section: Molecular Degree Ordersupporting
confidence: 81%
“…The increase in SOL also occurred in OPT-modified starch, which was in line with another study on OPT corn starch [18] and on OPT breadfruit starch [12]. OPT can inhibit starch gelatinization and swelling [44]. Furthermore, Pukkahuta et al [45] showed that a decrease in swelling of OPT was caused by a decrease in enthalpy of gelatinization, which increased the amorphous region of the starch granules.…”
Section: Molecular Degree Ordersupporting
confidence: 81%
“…Statistical significance of the models is demonstrated by the probability value ( p ‐value) using the F ‐value 45,46 . Lack of fit p ‐value shows that there is high nonsignificant lack of fit leading to a strong indication that the model fits adequately with the data obtained from experiment 47,48 . The highest lack of fit p ‐value presented in Tables 4 and 5 is 0.43 and 0.21, respectively, for the reduced cubic oleic acid conversion model and reduced quadratic selectivity of jet fuel range hydrocarbon model.…”
Section: Resultsmentioning
confidence: 99%
“…45,46 Lack of fit p-value shows that there is high nonsignificant lack of fit leading to a strong indication that the model fits adequately with the data obtained from experiment. 47,48 The highest lack of fit p-value presented in Tables 4 and 5 is 0.43 and 0.21, respectively, for the reduced cubic oleic acid conversion model and reduced quadratic selectivity of jet fuel range hydrocarbon model. The two highest lack of fit p-values are both greater than 0.05; hence, they reflect good model adequacy.…”
Section: Analysis Of Variance and Regression Models Developmentmentioning
confidence: 97%
“…Tuy nhiên, hạn chế của phương pháp là kết quả thường bị ảnh hưởng đồng thời bởi các yếu tố khảo sát, nên điều kiện cuối cùng chưa hẳn đã là điều kiện tối ưu nhất. Vì vậy, để khắc phục vấn đề này, phương pháp bề mặt đáp ứng (RSM -Response surface methodology) với thiết kế mô hình lặp tâm (CCD -Central composite design) là giải pháp tối ưu thay thế hiệu quả, được sử dụng nhiều trong tối ưu quy trình biến tính tinh bột [12].…”
Section: Mở đầUunclassified