2015
DOI: 10.1016/j.powtec.2015.06.034
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of spray drying process for formulation of solid dispersion containing polypeptide-k powder through quality by design approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
13
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 59 publications
(14 citation statements)
references
References 34 publications
1
13
0
Order By: Relevance
“…A funnel was clamped with its tip 7 cm above the surface. The tangent of the angle of repose was the ratio of the height of the heap of powder to the semi-diameter of the base of the heap of powder (Kaur et al, 2015).…”
Section: Angle Of Reposeimentioning
confidence: 99%
“…A funnel was clamped with its tip 7 cm above the surface. The tangent of the angle of repose was the ratio of the height of the heap of powder to the semi-diameter of the base of the heap of powder (Kaur et al, 2015).…”
Section: Angle Of Reposeimentioning
confidence: 99%
“…These droplets are going for evaporation process and produce SDs commercially available spray dryer such as incivek and intelence which is utilized for production of SDs. Kaur et al [41] had presented the formulation of SD containing polypeptide-k to enhance its aqueous solubility using trehalose and Tween-80 they had concluded that the optimized batch of formulation had exhibited higher solubility in water as well as various aqueous buffers as compared to pure polypeptide-k. Ramesh et al [42] had enhanced the dissolution rate of Etravirine by converting it from crystalline to amorphous form by spray drying method. They had used various polymers such as Solupus and Povidone which covert it into highly soluble amorphous form.…”
Section: Spray Dryingmentioning
confidence: 99%
“…The solutions were then filtered (cut-off 0.2 ”m, Ministart SRP 25, Sartorius) and analyzed. The studies were performed in triplicate and mean data were recorded [30]. "…”
Section: Micromeritic Characterization Of Powdersmentioning
confidence: 99%
“…Powder X-ray diffraction (PXRD) analysis "PXRD patterns were recorded as per Kaur et al [30]. In brief, CRM-R, CRM-NS (SD), and CRM-NS (SD) were recorded using an X-ray diffractometer (Bruker Axs, D8 Advance) with Cu line as the source of radiation.…”
Section: Micromeritic Characterization Of Powdersmentioning
confidence: 99%