2014
DOI: 10.1016/j.enbuild.2014.05.048
|View full text |Cite
|
Sign up to set email alerts
|

Optimizing commercial building participation in energy and ancillary service markets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
58
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(58 citation statements)
references
References 19 publications
0
58
0
Order By: Relevance
“…A number of studies have deployed the purely physical models such as EnergyPlus to achieve reducedorder RC (resistance-capacitance) models for simulating thermal dynamics and DR performance in commercial buildings [17,38,39,40,41,42,43]. Fast power demand response strategies that involve HVAC systems in commercial buildings were evaluated based on the RC model [44,45], which demonstrate that building HVAC systems are quite suitable for demand response.…”
Section: Current Approaches To Quantifying Building Dr Potentialmentioning
confidence: 99%
“…A number of studies have deployed the purely physical models such as EnergyPlus to achieve reducedorder RC (resistance-capacitance) models for simulating thermal dynamics and DR performance in commercial buildings [17,38,39,40,41,42,43]. Fast power demand response strategies that involve HVAC systems in commercial buildings were evaluated based on the RC model [44,45], which demonstrate that building HVAC systems are quite suitable for demand response.…”
Section: Current Approaches To Quantifying Building Dr Potentialmentioning
confidence: 99%
“…This could pose extra demand response incentives on this scale, in order to limit the stress on the distribution grid [23]. In a commercial building context, the magnitude of the electricity demand could be large enough such that direct interaction with the electricity system (on the generation and transmission level) is possible, for example for providing ancillary services [24].…”
Section: What Is the Right Scale In Thinking About A Smart Grid As Itmentioning
confidence: 99%
“…At instant k, the controller state estimates are available, thus J is a function of z k only. Since the regulation signal represents the change in the power consumed by the HVAC unit, u (6) where u Baseline k+i|k is the optimal value for the manipulated variable at ith prediction horizon step without considering the impact of the regulation signal, i.e. the optimal control signal such that the room air temperature is as close as possible to its set point.…”
Section: Control Design For a Vav Hvac Unitmentioning
confidence: 99%
“…The use of commercial building HVAC systems for providing ancillary services ia examined in [6][7][8][9][10][11][12][13][14][15][16][17][18]. In particular, the works in [6][7][8] address the usage of commercial buildings for demand response programs, which typically involve reduction of peak power in emergency situations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation