2023
DOI: 10.3389/frobt.2022.1099275
|View full text |Cite
|
Sign up to set email alerts
|

Organ curvature sensing using pneumatically attachable flexible rails in robotic-assisted laparoscopic surgery

Abstract: In robotic-assisted partial nephrectomy, surgeons remove a part of a kidney often due to the presence of a mass. A drop-in ultrasound probe paired to a surgical robot is deployed to execute multiple swipes over the kidney surface to localise the mass and define the margins of resection. This sub-task is challenging and must be performed by a highly-skilled surgeon. Automating this sub-task may reduce cognitive load for the surgeon and improve patient outcomes. The eventual goal of this work is to autonomously … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…The design of the PAF rail suction line used in this work is based on the optimisation study first presented in [ 8 , 27 ], and later iterations in [ 9 , 11 ]. In this version, we wanted to manufacture the rail in solid block colours such that the suction area and grasping fin are in one colour, and the rail is in another contrasting colour, as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The design of the PAF rail suction line used in this work is based on the optimisation study first presented in [ 8 , 27 ], and later iterations in [ 9 , 11 ]. In this version, we wanted to manufacture the rail in solid block colours such that the suction area and grasping fin are in one colour, and the rail is in another contrasting colour, as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The design of the PAF rail suction line used in this work is based on the optimisation study first presented in [8,27], and later iterations in [9,11]. In this version, we wanted to the contour are detected.…”
Section: Design and Fabrication Of The Paf Railmentioning
confidence: 99%
See 2 more Smart Citations
“…Similarly, McDonald-Bowyer et al incorporated an FBGS to track the deformation of a pneumatically-actuated silicon retractor during robotic-assisted laparoscopic surgery. Therefore providing means to correlate US images to the underlying organ morphology [79].…”
Section: Shape Sensingmentioning
confidence: 99%