2003
DOI: 10.1097/01.sap.0000041482.24205.d7
|View full text |Cite
|
Sign up to set email alerts
|

Osteosynthesis in Digital Replantation Using Bioabsorbable Rods

Abstract: There are several fixation techniques for osteosynthesis in digital replantation. Kirschner wire fixation is used commonly but the wires protrude and disturb mobilization. Moreover, it requires removal. Since February 1995, the authors have been using a bioabsorbable rod made of poly-L-lactide as an intramedullary nail for osteosynthesis in digital replantation. The advantages of this technique include the absence of protruding hardware that would require removal and technical simplicity. This method has been … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2004
2004
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 7 publications
0
4
0
2
Order By: Relevance
“…Normal function was regained in three children with a phalangeal neck fracture which was fixed with a non-SR PDS pin fixation (Vandenberk et al, 1996). Arata et al (2003a) used intramedullary PLLA rod for the fixation of arthrodesis or diaphyseal fractures in 26 cases of digital replantation. No cases of non-union or infection occurred, but in one patient a transient bone resorption was observed.…”
Section: Clinical Studiesmentioning
confidence: 99%
“…Normal function was regained in three children with a phalangeal neck fracture which was fixed with a non-SR PDS pin fixation (Vandenberk et al, 1996). Arata et al (2003a) used intramedullary PLLA rod for the fixation of arthrodesis or diaphyseal fractures in 26 cases of digital replantation. No cases of non-union or infection occurred, but in one patient a transient bone resorption was observed.…”
Section: Clinical Studiesmentioning
confidence: 99%
“…Perfusion 17,19,37,56 12. Success/survival 9,16,17,19,21,22, 13. Anastomosis success 18,45,49,56 14.…”
Section: Discussionmentioning
confidence: 99%
“…Effectiveness of milking device 50 20. Bone union 22,27 Domain: complication 1. Complication rate 9,22,28,29,31,33-36,38,53,58 2.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Auch der Einsatz resorbierbarer Polylactid-Stifte zur intramedullären Fixierung ist beschrieben 36 , 93 . Diese sind im Röntgenbild nicht sichtbar, weshalb bei der Frage nach einem Materialbruch eine Kernspinuntersuchung notwendig ist.…”
Section: Technikenunclassified