2022
DOI: 10.1016/j.csite.2022.101811
|View full text |Cite
|
Sign up to set email alerts
|

Outdoor performance evaluation of a novel photovoltaic heat sinks to enhance power conversion efficiency and temperature uniformity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 21 publications
0
4
0
1
Order By: Relevance
“…This was attributed to the higher value of h for the case of internal cooling than that for the natural and external cooling methods. The reduction in temperature of the Si solar cell achieved in this study has been compared with the results obtained by other cooling methods reported in the 27 Farhanet al, 28 Firoozzadeh et al, 29 Hasan et al, 30 Krstic et al, 31 AI-Amri et al, 32 Ahmad et al, 33 Raina et al, 34 Hernandez-Perez et al, 35 literature and is summarized in Table 2. Apparently, the internal active cooling method proposed in this study offered a relatively higher temperature reduction in comparison to passive cooling and analogous external active cooling methods.…”
Section: ■ Experimental Methodsmentioning
confidence: 67%
“…This was attributed to the higher value of h for the case of internal cooling than that for the natural and external cooling methods. The reduction in temperature of the Si solar cell achieved in this study has been compared with the results obtained by other cooling methods reported in the 27 Farhanet al, 28 Firoozzadeh et al, 29 Hasan et al, 30 Krstic et al, 31 AI-Amri et al, 32 Ahmad et al, 33 Raina et al, 34 Hernandez-Perez et al, 35 literature and is summarized in Table 2. Apparently, the internal active cooling method proposed in this study offered a relatively higher temperature reduction in comparison to passive cooling and analogous external active cooling methods.…”
Section: ■ Experimental Methodsmentioning
confidence: 67%
“…Thus, inverter input is adjusted to 600-650 Volt-40 Ampere voltage and current values when the panel surface is 50℃ under sunny day conditions. The design was made considering that the efficiency of the PV panel decreases between 0.25-0.5% with each 1°C increase in temperature [21]. The 3D design and layout designs of the roof-top type PV system designed with Solarius and PV*SOL program, which can output 25 kW of power, are as in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Studi tentang desain sirip baru untuk pendingin photovoltaic dan keseragaman suhu dilakukan oleh E.Z. Ahmad dkk dan dari penelitian tersebut didapatkan desain pendingin heat sinks dengan ujung berbentuk L mampu mendinginkan suhu photovoltaic pada suhu ruang terbuka dan mampu meningkatkan daya keluaran dari modul photovoltaic tersebut dibandingkan dengan photovoltaic tanpa pendingin [12]. Penggunaan heat sinks multi level pada modul photovoltaic yang diselidiki melalui metode elemen hingga (FEA).…”
Section: Pendahuluanunclassified