2010
DOI: 10.1042/ba20090369
|View full text |Cite
|
Sign up to set email alerts
|

Overloading ion‐exchange membranes as a purification step for monoclonal antibodies

Abstract: The present study examined the overloading of ion-exchange membrane adsorbers, a form of frontal chromatography, as the final purification step in the production of mAbs (monoclonal antibodies) produced from CHO (Chinese-hamster ovary) cells. Preferential binding of impurities over antibody product was exploited using commercially available cation- and anion-exchange membranes. Three different antibody feedstreams previously purified over Protein A and ion-exchange column chromatography were tested. Feedstream… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
28
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(28 citation statements)
references
References 23 publications
0
28
0
Order By: Relevance
“…For successful SDC on particulate chromatographic supports, flow rates must be five times lower to achieve optimal sample displacement compared to standard gradient elution separation [14]. On the contrary, flow rate-independent SDC for purification of monoclonal antibodies has been demonstrated with convective media [15]. Since SD effects on monoliths are independent of column size [10], they can be used for SDC of biomacromolecules at microanalytical, analytical and preparative scales.…”
Section: Introductionmentioning
confidence: 98%
“…For successful SDC on particulate chromatographic supports, flow rates must be five times lower to achieve optimal sample displacement compared to standard gradient elution separation [14]. On the contrary, flow rate-independent SDC for purification of monoclonal antibodies has been demonstrated with convective media [15]. Since SD effects on monoliths are independent of column size [10], they can be used for SDC of biomacromolecules at microanalytical, analytical and preparative scales.…”
Section: Introductionmentioning
confidence: 98%
“…On the other hand, BaSO 4 precipitate of plasma of Atlantic salmon was a relative complex protein mixture that was used as a starting material for isolation of highly pure and biologically active thrombin by use of SDS as a rapid, simple and cost-effective method [21]. Brown et al [28] recently used ion-exchange membrane chromatography under overloading conditions for purification of monoclonal antibodies. The overloading of membranes results in binding of impurities, and breakthrough of purified antibody.…”
Section: Discussionmentioning
confidence: 99%
“…The use of membranes and monoliths for SDC can be very favorable because the displacement phenomena by sample components with different affinities for the stationary phase occurs at much lower loading than if bulk, porous chromatographic supports are employed [44, 45, 51]. A similar phenomenon is also observed when non-porous bulk supports are used [51, 52].…”
Section: Principles Of Sample Displacement Chromatographymentioning
confidence: 99%
“…After optimization of sample load and application buffers (starting pH value and salt concentration), highly pure ITIp concentrate was isolated from a side-fraction that is produced during clotting factor IX (FIX) preparation. The industrial-scale use of membranes for SDC in ion-exchange mode for the purification of antibodies was demonstrated by Brown et al [45]. …”
Section: Applications Of Sample Displacement Chromatographymentioning
confidence: 99%
See 1 more Smart Citation