2022
DOI: 10.1016/j.trac.2022.116693
|View full text |Cite
|
Sign up to set email alerts
|

Overview on microfluidics devices for monitoring brain disorder biomarkers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 78 publications
0
7
0
Order By: Relevance
“…Since the current response has submillisecond resolution and high sensitivity, microelectrode amperometric analysis was performed for conditions such as single cell analysis and single exocytotic reaction. 214 Tosar et al have revealed an amperometry process for determining the exosome. Rabbit polyclonal α-human CD9 antibodies were modified on substrates to detect exosomes and mouse monoclonal α-human CD9 antibodies attached to the residual CD9 fragments exposed on the exosome surface.…”
Section: ■ Exosome Detection By Sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the current response has submillisecond resolution and high sensitivity, microelectrode amperometric analysis was performed for conditions such as single cell analysis and single exocytotic reaction. 214 Tosar et al have revealed an amperometry process for determining the exosome. Rabbit polyclonal α-human CD9 antibodies were modified on substrates to detect exosomes and mouse monoclonal α-human CD9 antibodies attached to the residual CD9 fragments exposed on the exosome surface.…”
Section: ■ Exosome Detection By Sensorsmentioning
confidence: 99%
“…The increase or decrease of the current signal proportional to the reaction rate indicates the reduction or oxidation reactions. Since the current response has submillisecond resolution and high sensitivity, microelectrode amperometric analysis was performed for conditions such as single cell analysis and single exocytotic reaction . Tosar et al have revealed an amperometry process for determining the exosome.…”
Section: Exosome Detection By Sensorsmentioning
confidence: 99%
“…[53] a. Repeatability expresses the degree to which independent results obtained using the same procedure on identical samples concur with one another under the same settings (operator, laboratory, and after short intervals of time) b. Reproducibility expresses the closeness of agreement between independent results obtained with the same method on identical samples but under different conditions (analysts, laboratories, and/or after different intervals of time). [54] Precision can be expressed in terms of variance, standard deviation, or the coefficient of variation (CV). The smaller the variance or standard deviation, the higher the precision.…”
Section: Analytical Figures Of Meritmentioning
confidence: 99%
“…Droplet-based microfluidic devices are critical in research areas such as bioanalysis (Sharma & Sharma 2022;Xu et al 2022;Sun et al 2023), disease surveillance (Giuffrida, Cigliana & Spoto 2018;Nix et al 2022), the synthesis of nanomaterials (Zou et al 2022;Gimondi et al 2023;Yao et al 2023) and microchemical reactors (Whitesides 2006;Verma & Pandya 2022). In these areas, droplets with controlled volume and good uniformity are prerequisites for ensuring device accuracy and sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…In practical applications, fabrication defects inevitably exist in microchannels, which not only result in asymmetry between the two branch channels, but also generate daughter droplets of different volumes. Although active agents or surfactants are known to promote droplet breakup and prevent droplets from coalescing (Baret et al 2009;Pan et al 2016), their effects on the disturbed flow field, neck contraction process and enhancement or weakening of the disturbances caused by tiny deficiencies and defects are still unclear. Therefore, it is necessary to understand the effect of surfactants on the passive breakup of a droplet in a T-junction microchannel, which is helpful for controlling the surfactant dosage and generating droplets with controlled volume.…”
Section: Introductionmentioning
confidence: 99%