Pacemaker reuse: an initiative to help those in underserved nations in need of life-saving device therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 17 publications
0
3
0
1
Order By: Relevance
“…Rates of malfunction for reused devices have been found in prior studies to be no higher than that for new devices. The increased rate of malfunction found in the recent meta-analysis while concerning, is a risk believed to be acceptable for patients in dire need of bradyarrhythmia therapy in LMICs[10]. PMHYH is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support.…”
Section: Resultsmentioning
confidence: 99%
“…Rates of malfunction for reused devices have been found in prior studies to be no higher than that for new devices. The increased rate of malfunction found in the recent meta-analysis while concerning, is a risk believed to be acceptable for patients in dire need of bradyarrhythmia therapy in LMICs[10]. PMHYH is poised to conduct a prospective randomized, non-inferiority, multicenter study to confirm the clinical efficacy and safety of pacemaker reuse, for clinical and legal support.…”
Section: Resultsmentioning
confidence: 99%
“…14 Mais de sessenta mil aparelhos são explantados por ano nos Estados Unidos, e há uma estimativa de que cerca de 20% destes poderiam ser reutilizados, gerando um total anual de 10 a 12 mil aparelhos-ano. [15][16][17] Embora a doação de geradores de marca-passos seja viável, a reutilização de eletrodos é bem mais difícil. Eletrodos são, em geral, difíceis de serem retirados devido ao processo de fibrose causado ao longo do tempo após o seu implante, e a sua extração é potencialmente danosa a eles.…”
Section: Reutilização De Dispositivos Cardíacosunclassified
“…In fact, the US FDA has labeled pacemakers and defibrillators as "singleuse devices" and describes CIED reuse as an "objectionable practice," and there appears little enthusiasm among US manufacturers for a change in the federal perspective. 18,19 Nevertheless, we believe that a more sustainable approach to CIED reutilization is possible given that a majority of deceased hospital autopsy patients with CIEDs in the United States exhibit normal functionality and a remaining longevity estimate ≥4 years. For such an endeavor to be truly successful in both volume and quality, it would be most helpful for several interested academic medical centers to form a national "CIED donor network."…”
Section: Current Regulatory Climatementioning
confidence: 99%
“…We also agree with recent calls for regulatory exemptions to absolve manufacturers of liability for a product's long-term performance beyond the scope of its original single-use warranty when they endeavor to assist with quality control analysis as part of such humanitarian efforts. [17][18][19][20] …”
Section: Current Regulatory Climatementioning