2017
DOI: 10.1016/j.snb.2017.04.126
|View full text |Cite
|
Sign up to set email alerts
|

Paper-based chemiluminescence immunodevice with temporal controls of reagent transport technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
29
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(30 citation statements)
references
References 51 publications
1
29
0
Order By: Relevance
“…The fluid control method with surfactants and dissolving materials, such as sucrose, has the advantage of being simple in structure, but using materials, such as ethanol, as mentioned in previous studies, may affect samples or downstream reactions. However, if verified materials, such as tween, which is often utilized in immunoassay using various antibodies, or sucrose, which is widely applied to dry and preserve antibody conjugates used in multi-step reactions, such as ELISA, are used, accurate assays can be performed without any significant impact on downstream action [49,61]. In addition, optimizing the deposition concentration of the surfactant or sugar has little effect on valve opening, on the solubility of each reagent, or on delivery capability, thus showing In addition to fluid velocity control technology, switching methods using the principle of linking disconnected parts or blocking channels are also widely used in passive fluid manipulation technology.…”
Section: Dissolvable Materials (Sucrose) Fluid Velocity Controlmentioning
confidence: 99%
“…The fluid control method with surfactants and dissolving materials, such as sucrose, has the advantage of being simple in structure, but using materials, such as ethanol, as mentioned in previous studies, may affect samples or downstream reactions. However, if verified materials, such as tween, which is often utilized in immunoassay using various antibodies, or sucrose, which is widely applied to dry and preserve antibody conjugates used in multi-step reactions, such as ELISA, are used, accurate assays can be performed without any significant impact on downstream action [49,61]. In addition, optimizing the deposition concentration of the surfactant or sugar has little effect on valve opening, on the solubility of each reagent, or on delivery capability, thus showing In addition to fluid velocity control technology, switching methods using the principle of linking disconnected parts or blocking channels are also widely used in passive fluid manipulation technology.…”
Section: Dissolvable Materials (Sucrose) Fluid Velocity Controlmentioning
confidence: 99%
“…The reproducibility is similar to those obtained in a previous study using a sugar barrier. 8 The surface topography of the microgrooved channel (N = 10) was examined by field-emission scanning electron microscopy (FE-SEM; JSM-6700FZ, JEOL) and digital microscopy (VHX-5000, Keyence). Figures 4(c) and 4(d) show SEM images and a 3D profile of the grooved surface (N = 10).…”
Section: Flow Rate Measurementmentioning
confidence: 99%
“…Since paper was introduced as a fluidic control device 1 for biochemical assays, paper-based fluidic devices [2][3][4][5][6][7][8][9][10][11] have been developed as a new diagnostic platform and fluid flow control technique because such systems require no external power or off-chip components and include no moving parts.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations