2019
DOI: 10.1016/j.trac.2019.06.028
|View full text |Cite
|
Sign up to set email alerts
|

Paper spray ionization: Applications and perspectives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(58 citation statements)
references
References 54 publications
0
58
0
Order By: Relevance
“…Compare to other methods in the same group, PSI has shown the greatest potential for quantitative analysis [9]. Since the invention of PSI by the Cooks group in 2010 [10], PSI has been applied widely in several fields of analytical chemistry such as clinical, food, forensic, environmental, mechanistic, and reaction monitoring studies [11].…”
Section: Figure 1 Classification Of Desorption Methods In Ai-msmentioning
confidence: 99%
“…Compare to other methods in the same group, PSI has shown the greatest potential for quantitative analysis [9]. Since the invention of PSI by the Cooks group in 2010 [10], PSI has been applied widely in several fields of analytical chemistry such as clinical, food, forensic, environmental, mechanistic, and reaction monitoring studies [11].…”
Section: Figure 1 Classification Of Desorption Methods In Ai-msmentioning
confidence: 99%
“…Paper spray ionization (PSI) [95] is another form of ambient ionization, where ions of an analyte are formed by applying a high potential to a triangular paper dropped with a small volume (<10 μL) of solution. Samples are either preloaded on the paper or added via a spray solution [96] .…”
Section: Electrochemistry In Ms Ion Sourcesmentioning
confidence: 99%
“…The method of PS‐MS, a direct, ambient ionization method that is relatively new, evolved from initial work by Cooks and Ouyang at Purdue University in 2010 . Its applications are broad and continually growing, extending to environmental, forensic, biological, and industrial areas, amongst others . In PS‐MS, laborious sample preparations are largely obviated, as raw sample is simply deposited directly onto a triangular piece of paper by swiping, micropipetting, etc.…”
Section: Overview Of Ps‐ms Techniquementioning
confidence: 99%
“…In addition to minimized matrix effects for complex samples over wide concentration ranges, PS‐MS routinely achieves picogram level detection limits . This level of sensitivity may initially seem unnecessary for drug checking, given that typical lethal human doses of fentanyl and related analogs occur at microgram to milligram levels .…”
Section: Sensitivity and Quantitative Capabilitiesmentioning
confidence: 99%