Paper spray mass spectrometry for the analysis of picoliter droplets

Abstract: Paper spray ionization coupled with high resolution mass spectrometry is shown to be an effective strategy for the analysis of picoliter droplets containing atmospherically-relevant oxygenated organic compounds.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
29
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(30 citation statements)
references
References 54 publications
1
29
0
Order By: Relevance
“…Two complementary ionization sources are used in these experiments: paper spray ionization 50,54,55 and thermal desorption coupled to helium glow discharge ionization. 50,56 Development and use of these ion sources for detection of single micron-sized droplets is described in detail in Jacbos et al, 51 Kohli & Davies 54,55 and Willis et al 50 Their operation is summarized below.…”
Section: Single Droplet Ambient Ionization Mass Spectrometry All Meas...mentioning
confidence: 99%
“…Two complementary ionization sources are used in these experiments: paper spray ionization 50,54,55 and thermal desorption coupled to helium glow discharge ionization. 50,56 Development and use of these ion sources for detection of single micron-sized droplets is described in detail in Jacbos et al, 51 Kohli & Davies 54,55 and Willis et al 50 Their operation is summarized below.…”
Section: Single Droplet Ambient Ionization Mass Spectrometry All Meas...mentioning
confidence: 99%
“…Impact of solvent and spray tip position on single droplet detection PS-MS specific considerations for reproducibility are spray stability and droplet deposition location 37 . Negative ion mode PS-MS has intrinsic challenges related to the high current involved, and addition of CHCl 3 to the spray solvent has been shown to mitigate the formation of corona discharges from fibres at the spray tip 44,55 .…”
Section: Detection Of Single Aqueous Dropletsmentioning
confidence: 99%
“…With negative ion mode PS-MS, positively charged single droplets are ejected from the QET and are attracted toward the spray tip. The deposition location of droplets on the paper substrate impacts both the single droplet event timescale and reproducibility, as described for free-falling neutral droplets by Kaur Kohli and Davies 37 . We observe good reproducibility in droplet signals with the spray tip positioned in line with the edge of the QET outlet, such that droplets likely land slightly behind the spray tip 37 .…”
Section: Detection Of Single Aqueous Dropletsmentioning
confidence: 99%
See 2 more Smart Citations