Paracetamol Sensing with a Pencil Lead Electrode Modified with Carbon Nanotubes and Polyvinylpyrrolidone

Abstract: The determination of paracetamol is a common need in pharmaceutical and environmental samples for which a low-cost, rapid, and accurate sensor would be highly desirable. We develop a novel pencil graphite lead electrode (PGE) modified with single-wall carbon nanotubes (SWCNTs) and polyvinylpyrrolidone (PVP) polymer (PVP/SWCNT/PGE) for the voltammetric quantification of paracetamol. The sensor shows remarkable analytical performance in the determination of paracetamol at neutral pH, with a limit of detection of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 60 publications
0
13
0
Order By: Relevance
“…Electrical contact with the instrument is realized by means of a conductive wire which was soldered or wrapped to the metallic part of the mechanical pencil holder [9,19,21,22,[24][25][26][27][28][29][30][31][32][33][34][35][36][37] (Figure 1a). A micropipette tip [38], an insuline syringe [39], a glass cappilary [40,41], or a plastic [16,[42][43][44][45][46] (Figure 1b) or Teflon tube [47][48][49][50][51][52] (Figure 1c,d) can also act as holder. An araldite mixture (epoxy resin, 1:1) [16,41,[43][44][45], bentonite [38,39], or cyanoacrylate glue [40] was used to fix the graphite lead into the support.…”
Section: Pge Manufacturing Proceduresmentioning
confidence: 99%
See 4 more Smart Citations
“…Electrical contact with the instrument is realized by means of a conductive wire which was soldered or wrapped to the metallic part of the mechanical pencil holder [9,19,21,22,[24][25][26][27][28][29][30][31][32][33][34][35][36][37] (Figure 1a). A micropipette tip [38], an insuline syringe [39], a glass cappilary [40,41], or a plastic [16,[42][43][44][45][46] (Figure 1b) or Teflon tube [47][48][49][50][51][52] (Figure 1c,d) can also act as holder. An araldite mixture (epoxy resin, 1:1) [16,41,[43][44][45], bentonite [38,39], or cyanoacrylate glue [40] was used to fix the graphite lead into the support.…”
Section: Pge Manufacturing Proceduresmentioning
confidence: 99%
“…A micropipette tip [38], an insuline syringe [39], a glass cappilary [40,41], or a plastic [16,[42][43][44][45][46] (Figure 1b) or Teflon tube [47][48][49][50][51][52] (Figure 1c,d) can also act as holder. An araldite mixture (epoxy resin, 1:1) [16,41,[43][44][45], bentonite [38,39], or cyanoacrylate glue [40] was used to fix the graphite lead into the support. Other PGEs were obtained by covering a part of the graphite lead with nail polish [53] or with Teflon tape [20,[54][55][56][57][58][59][60][61][62][63][64][65] (Figure 1e), leaving a constant length and area of nacked pencil mine to act as an electroative surface.…”
Section: Pge Manufacturing Proceduresmentioning
confidence: 99%
See 3 more Smart Citations