2019
DOI: 10.1117/1.oe.58.9.094103
|View full text |Cite
|
Sign up to set email alerts
|

Parallel measurement of multiple linear polarization modes in few-mode optical fibers using spatial light modulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…However, it is challenging to investigate the modal components at the multimode output fiber, owing to the immaturity of the equipments and technologies in our laboratory. This issue could be addressed in the future by utilizing schemes adopted in [39][40][41][42][43][44][45].…”
Section: Multimode Qml Operationmentioning
confidence: 99%
“…However, it is challenging to investigate the modal components at the multimode output fiber, owing to the immaturity of the equipments and technologies in our laboratory. This issue could be addressed in the future by utilizing schemes adopted in [39][40][41][42][43][44][45].…”
Section: Multimode Qml Operationmentioning
confidence: 99%
“…The CSE method [20] is based on the conjugate symmetric extension property [22]. The method starts from a block mode matrix that is compiled for several modes ψ m .…”
Section: Conjugate Symmetric Extensionmentioning
confidence: 99%
“…a) b) c) by introducing a spatial frequency shift into a phase mask, which is used to overcome the limitation of phaseonly SLMs, thus encoding both phase and amplitude of a selected mode, 16 or for the parallel measurement of several modes. 10,13 However, the problem is that the position of the capturing point is hard to determine in an experiment, especially in the case of speckled beams. The difficulty is worsened by the high sensitivity of the decomposition results with respect to any positioning error.…”
Section: Point Of Interestmentioning
confidence: 99%
“…In addition, multiple amplitudes can be measured in parallel from one shot. 10 In this work, we propose and apply the MD with phase-only SLM digital holography generation to the study of the Kerr beam self-cleaning effect. 11 The impact of the phase-mask size, and of the true meaning point search procedure are among the several crucial factors that affect the accuracy of the MD procedure, and they will be discussed in details in our presentation.…”
Section: Introductionmentioning
confidence: 99%