2019
DOI: 10.1002/mrm.27905
|View full text |Cite
|
Sign up to set email alerts
|

Parallel transmission to reduce absorbed power around deep brain stimulation devices in MRI: Impact of number and arrangement of transmit channels

Abstract: Purpose To assess the mean and variance performance of parallel transmission (pTx) coils for reduction of the absorbed power around electrodes (APAE) in patients implanted with deep brain stimulation (DBS) devices. Methods We simulated 4 pTx coils (8 and 16 channels, head and body coils) and a birdcage body coil. We characterized the RF safety risk using the APAE, which is the integral of the deposited power (in Watts) in a small cylindrical volume of brain tissue surrounding the electrode tips. We assessed th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
39
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(39 citation statements)
references
References 54 publications
0
39
0
Order By: Relevance
“…Recent years have witnessed a spike in attempts to mitigate the problem of MRIinduced implant heating. Most of these efforts have focused to modify the geometry, structure or material of implants to suppress induced currents [12][13][14] or to alter the MRI hardware to reduce its interaction with the implant [4,11,[15][16][17][18][19][20][21][22][23][24][25][26][27][28].…”
Section: Resultsmentioning
confidence: 99%
“…Recent years have witnessed a spike in attempts to mitigate the problem of MRIinduced implant heating. Most of these efforts have focused to modify the geometry, structure or material of implants to suppress induced currents [12][13][14] or to alter the MRI hardware to reduce its interaction with the implant [4,11,[15][16][17][18][19][20][21][22][23][24][25][26][27][28].…”
Section: Resultsmentioning
confidence: 99%
“…In the case of elongated implants, such as leads in neuromodulation and cardiac devices, the distribution of MRI electric field E along the length of the implant has been shown to play a determinant role in the prediction of RF heating at the lead's tip 7,30 . This fact has been indeed exploited to introduce MRI field-shaping methods that manipulate the electric field of MRI transmitter to reduce its interaction with implanted leads 25, [49][50][51][52] , and in lead management techniques that attempt to modify lead trajectories to achieve the same purpose 3,53 .…”
Section: Discussionmentioning
confidence: 99%
“…Modeling and simulation in MRI have been used amply in the development and validation of novel MRI technology. 344 352 With the advancement of phantoms in becoming more and more realistic, VCTs will find even more applications in MRI.…”
Section: Vct Applicationsmentioning
confidence: 99%