2017
DOI: 10.1109/tpwrs.2016.2608904
|View full text |Cite
|
Sign up to set email alerts
|

Parameter Estimation of Resonant Fault Current Limiter for Protection and Stability Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…The simulation for fault detection and mitigation based on the RFCL is based on the transmission line presented in the Simulink model of Fig. 1 were performed not by estimating the parameters of the RFCL as previously done [17], but by varying the component parameters and the short circuit current level so that the critical fault-clearing time can be estimated. The procedure for fault detection is presented first, and then the appropriate mitigation is presented next.…”
Section: A Simulation Procedures For Fault Detection and Mitigation Using Rfclmentioning
confidence: 99%
“…The simulation for fault detection and mitigation based on the RFCL is based on the transmission line presented in the Simulink model of Fig. 1 were performed not by estimating the parameters of the RFCL as previously done [17], but by varying the component parameters and the short circuit current level so that the critical fault-clearing time can be estimated. The procedure for fault detection is presented first, and then the appropriate mitigation is presented next.…”
Section: A Simulation Procedures For Fault Detection and Mitigation Using Rfclmentioning
confidence: 99%
“…Similarly, few literatures are available on the impact of FCLs and possible remedial measures for the performance of the distance relay. In [18], the impact of resonant FCL on protection and stability is addressed, and associated parameters are estimated. In [19, 20], the impact of superconducting FCL (SFCL) on the performance of distance relay is evaluated by analytical and through simulation studies.…”
Section: Introductionmentioning
confidence: 99%
“…In paper, methods of determining location and design of superconducting fault current limiter (SFCL) have been proposed, which helps to recover system voltage of the DIFG system. Many FCL like current limiting reactors, superconducting FCL, solid state FCL, and hybrid FCL are engaged with the FRT to make the DFIG system connected during the fault . The application of the current‐limiting reactor is to introduce the reactor in series with the line for limiting the fault current.…”
Section: Introductionmentioning
confidence: 99%
“…Many FCL like current limiting reactors, superconducting FCL, solid state FCL, and hybrid FCL are engaged with the FRT to make the DFIG system connected during the fault. 9,[22][23][24] The application of the current-limiting reactor is to introduce the reactor in series with the line for limiting the fault current. With some hardware modification in the current-limiting reactors, it behaves as one of the high-temperature superconductor (HTS) FCL.…”
mentioning
confidence: 99%