“…Unfortunately, the heterogeneity of laser parameters and the discordant, and in some cases unclear therapeutic procedures as well as the unspecified features of the probe, hand-piece, or fiber employed for laser administration, did not allow for an intergroup analysis of the studies. A major problem in PBM, as carefully reported by Tuner and Jenkins [ 84 ], is the lack of proper reporting of the parameters, which does not enable reproducibility of the experimental results. Previously, we showed [ 85 ] that fluence per se did not predict the photobimodulatory effect of laser light on the cell, but a precise relation exists between laser power and duration of exposure.it was found that ”the energy has two-component power and time of exposure, and it has been demonstrated that there is not necessarily reciprocity between them and expected effects.…”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, the heterogeneity of laser parameters and the discordant, and in some cases unclear therapeutic procedures as well as the unspecified features of the probe, hand-piece, or fiber employed for laser administration, did not allow for an intergroup analysis of the studies. A major problem in PBM, as carefully reported by Tuner and Jenkins [ 84 ], is the lack of proper reporting of the parameters, which does not enable reproducibility of the experimental results. Previously, we showed [ 85 ] that fluence per se did not predict the photobimodulatory effect of laser light on the cell, but a precise relation exists between laser power and duration of exposure.it was found that ”the energy has two-component power and time of exposure, and it has been demonstrated that there is not necessarily reciprocity between them and expected effects.…”
Section: Discussionmentioning
confidence: 99%
“…Unfortunately, many of the prior studies have failed to report relevant treatment parameters due to inadequate understanding of critical dose characteristics. Nonetheless, it is now strongly recommended that a comprehensive treatment variables be carefully assessed and fully reported .…”
Section: Discussionmentioning
confidence: 99%
“…In terms of the physical determinants of the light device, there is increased appreciation in the field of the device and dose delivery parameters (Arany, ; Jenkins & Carroll, ; Tuner & Jenkins, ). Among these, the use of a small spot size of laser results in various empirical scanning patterns clinically that are difficult to precisely reproduce.…”
Section: Photobiomodulation Therapy In Oral Diseasesmentioning