Parameters estimation of electric arc furnace based on an analytical solution of power balance equation

Abstract: Summary A closed‐form solution for power balance equation of electric arc furnace (EAF) is proposed in this paper based on field measurements of the instantaneous furnace voltage and current. The method is developed based on an analytical solution of power balance equation in general case. The closed‐form solution is dependent on the EAF parameters, which should be found by parameter identification procedure carrying out by minimization of an appropriate objective function. The minimization is performed by mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 32 publications
0
9
0
Order By: Relevance
“…Manchur [13] Alkaran [14] Marulanda [15] Esfahani [16] Golestani [17] Illahi [18] Samet [19] Deepak [20] Dietz [21] Non-linear…”
Section: A) Linearity Versus Non-linearitymentioning
confidence: 99%
See 1 more Smart Citation
“…Manchur [13] Alkaran [14] Marulanda [15] Esfahani [16] Golestani [17] Illahi [18] Samet [19] Deepak [20] Dietz [21] Non-linear…”
Section: A) Linearity Versus Non-linearitymentioning
confidence: 99%
“…In fact, in a dynamic model, the electrical quantities in the previous moments are used. Some of the dynamic models are proposed in [14,15,17,[19][20][21]. c) Time-constant versus time-varying parameters Time-varying parameters cause flicker.…”
Section: B) Dynamic Versus Staticmentioning
confidence: 99%
“…Accordingly, EAF causes power quality problems in the supply network, such as voltage and current imbalances [6], harmonics [7,8], and voltage flicker [9][10][11]. To investigate the EAF's adverse effects in the point of common coupling (PCC) and provide appropriate solutions to deal with the disturbances, using precise EAF mathematical models and implementing the EAF in specialized simulation software is essential [12][13][14]. Although several studies have been done in the field of EAFs, there is a research gap in selecting an appropriate model incorporating a suitable simulation environment.…”
Section: Motivation and Incitementmentioning
confidence: 99%
“…In (13), Δt and T denote the duration of simulation steps and the simulation step number. By arranging (13), the arc current is calculated at any moment based on the arc current and arc voltage at the previous step as given in…”
Section: V(t) − V a (T) � L Eqmentioning
confidence: 99%
“…Electric arc furnace (EAF) is considered as one of the largest reactive power loads in the power systems globally . EAF is a harmonic‐rich nonlinear load from voltage and current points of view . Moreover, an EAF requires large, time‐varying, and nondeterministic reactive power to operate .…”
Section: Introductionmentioning
confidence: 99%