2011
DOI: 10.1016/j.athoracsur.2011.01.052
|View full text |Cite
|
Sign up to set email alerts
|

Patients With Severe Aortic Valve Stenosis and Impaired Platelet Function Benefit From Preoperative Desmopressin Infusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
83
1
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
3
2

Relationship

0
10

Authors

Journals

citations
Cited by 59 publications
(88 citation statements)
references
References 34 publications
3
83
1
1
Order By: Relevance
“…The standard dose is 0.3 µg/kg diluted in 50 ml saline and infused over 30 minutes [451]. Recently, it was shown that identification of impaired platelet function with a platelet function analyzer PFA-100 [454] or whole blood multiple electrode aggregometer [455] might be helpful in the identification of patients who may benefit from desmopressin therapy. The combined effect of platelet concentrates and subsequent administration of desmopressin has also been advocated to enhance the recovery of normal platelet function [456].…”
Section: Resultsmentioning
confidence: 99%
“…The standard dose is 0.3 µg/kg diluted in 50 ml saline and infused over 30 minutes [451]. Recently, it was shown that identification of impaired platelet function with a platelet function analyzer PFA-100 [454] or whole blood multiple electrode aggregometer [455] might be helpful in the identification of patients who may benefit from desmopressin therapy. The combined effect of platelet concentrates and subsequent administration of desmopressin has also been advocated to enhance the recovery of normal platelet function [456].…”
Section: Resultsmentioning
confidence: 99%
“…Assessment of platelet dysfunction with PFA-100 in different clinical setting or in patients undergoing different kinds of elective surgeries, may provide useful information for postoperative blood transfusion management [106,107] . Especially in cardiac surgery PFA methodology showed a high predictive value of platelet function for management of intra-and postoperative blood loss [108][109][110][111] . In patients with biventricular assist device implantation on treatment with clopidogrel, the strict monitoring of impaired platelet function with this method (by using CADP cartridge) allowed them to go under successful transplantation with no major blood loss [112] .…”
Section: Platelet Function Point-of-care Testingmentioning
confidence: 99%
“…DDAVP and replacement of VWF may reduce bleeding symptoms in children with high shear stress lesions and reduced levels of high-molecular-weight multimers. In a double-blind, placebo-controlled trial, DDAVP was shown to reduce bleeding in adults undergoing aortic valve replacement for aortic stenosis, 32 although only a small subset of these patients had proven AVWS. Further, the risk of DDAVP-induced fluid overload and hyponatremia in the setting of these major surgeries should always be considered.…”
Section: Treatment Of Avws Caused By a Cardiovascular Diseasementioning
confidence: 99%