2002
DOI: 10.1021/ac022035i
|View full text |Cite
|
Sign up to set email alerts
|

Peer Reviewed: Analytical Applications of Single-Molecule Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 51 publications
(36 citation statements)
references
References 34 publications
0
36
0
Order By: Relevance
“…Specifically, 2 to 23 single-molecule measurements, depending on the experimental uncertainty (CV pop ), provides a mean estimate with an associated CV mean within 1% of CV pop (i.e., the CV error limit ϭ ⌬CV Ͻ 1%). 3 The population mean and CV were determined from replicate simulations of data sets containing 10 4 measurements for each value of CV exp . The number of measurements used to determine pop and CV pop , 10 4 , was based on the number required to obtain a 1% CV for Poisson-limited measurements (8) and the typical size of flow cytometry data sets used below.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Specifically, 2 to 23 single-molecule measurements, depending on the experimental uncertainty (CV pop ), provides a mean estimate with an associated CV mean within 1% of CV pop (i.e., the CV error limit ϭ ⌬CV Ͻ 1%). 3 The population mean and CV were determined from replicate simulations of data sets containing 10 4 measurements for each value of CV exp . The number of measurements used to determine pop and CV pop , 10 4 , was based on the number required to obtain a 1% CV for Poisson-limited measurements (8) and the typical size of flow cytometry data sets used below.…”
Section: Resultsmentioning
confidence: 99%
“…Notably, the number of single-molecule detection (SMD) studies examining biomolecules has steadily increased in recent years, with several articles in an issue of Science addressing this topic (1). Additional information and recent progress in the field of SMD is summarized in several review articles (2)(3)(4)(5)(6)(7).…”
mentioning
confidence: 99%
“…Current commercial flow cytometers are capable of detecting a minimum level of a few hundred fluorescein molecules per particle. Some custom cytometry systems have reported single fluorophore molecule detection, but this level of sensitivity is not widely available (29). With single nanoparticle scattering intensities on the order of 10 5 fluorescein molecules, commercial flow cytometers theoretically can detect single nanoparticle labels (4).…”
Section: Discussionmentioning
confidence: 99%
“…Scaffold (version Scaffold_3_00_08, Proteome Software Inc.) was used to validate MS/MS based peptide and protein identifications. Peptide identifications were accepted if they could be established at greater than 95.0% probability as specified by the Peptide Prophet algorithm (Keller et al, 2002). Protein identifications were accepted if they could be established at greater than 99.0% probability and contained at least 2 identified peptides.…”
Section: Proteomics Of Dvl3-based Supermolecular Complexesmentioning
confidence: 99%