2011
DOI: 10.4172/2155-9929.1000104
|View full text |Cite
|
Sign up to set email alerts
|

Peptide Aptamer-Based ELISA-Like System for Detection of Cathepsin E in Tissues and Plasma

Abstract: ELISA (enzyme-linked immunosorbent assay), a highly sensitive and powerful molecular detection tool, has been constructed based on antibodies, as its name denotes. However, it is not so easy to prepare antibodies for any target molecule and there are still problems in their cost and stability. In this study, peptide-based ELISA-like systems (pep-ELISA) were first constructed and shown to be effective. In particular, if the target is an enzyme, such as cathepsin E, that can generate a fluorescent product, the c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…To address these challenges, a microfluidic approach can be used to reduce the possible non-specific interactions. Our sensor provided an improvement of sensitivity of serum CatE by at least three orders of magnitude compared to a conventional ELISA system using a similar peptide aptamer 19 . Given this observation and with implementation of further improvements in the sampling process, our peptide-modified SWCNT FET biosensor could offer an attractive approach to detect CatE in a real clinical sample with higher selectivity and the desired sensitivity.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…To address these challenges, a microfluidic approach can be used to reduce the possible non-specific interactions. Our sensor provided an improvement of sensitivity of serum CatE by at least three orders of magnitude compared to a conventional ELISA system using a similar peptide aptamer 19 . Given this observation and with implementation of further improvements in the sampling process, our peptide-modified SWCNT FET biosensor could offer an attractive approach to detect CatE in a real clinical sample with higher selectivity and the desired sensitivity.…”
Section: Resultsmentioning
confidence: 96%
“…Our device exhibited good selectivity (no response for bovine serum albumin (BSA) and cathepsin K (CatK)) and a low detection limit. The sensitivity of this device could improve the limit of detection of CatE in human serum by at least three orders of magnitude compared with a conventional ELISA-based system using a similar peptide aptamer 19 .
Figure 1 Schematic of the concept.
…”
Section: Introductionmentioning