2018
DOI: 10.1016/j.dib.2018.04.018
|View full text |Cite
|
Sign up to set email alerts
|

Peptidomics dataset: Blood plasma and serum samples of healthy donors fractionated on a set of chromatography sorbents

Abstract: Blood as connective tissue potentially contains evidence of all processes occurring within the organism, at least in trace amounts (Petricoin et al., 2006) [1]. Because of their small size, peptides penetrate cell membranes and epithelial barriers more freely than proteins. Among the peptides found in blood, there are both fragments of proteins secreted by various tissues and performing their function in plasma and receptor ligands: hormones, cytokines and mediators of cellular response (Anderson et al., 2002)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 8 publications
1
16
0
Order By: Relevance
“…These identification rates are comparable to or exceed those reported by other plasma peptidomics studies. 4952…”
Section: Discussionmentioning
confidence: 99%
“…These identification rates are comparable to or exceed those reported by other plasma peptidomics studies. 4952…”
Section: Discussionmentioning
confidence: 99%
“…The analysis was performed on a Triple Time-of-Flight (TOF) 5600+ mass spectrometer with a NanoSpray III ion source (AB Sciex, Framingham, MA, USA) coupled with a NanoLC Ultra 2D+ nano-high performance liquid chromatography (HPLC) system (Eksigent, now part of Sciex, Framingham, MA, USA), as we have described previously [ 23 , 76 ]. The HPLC system was set in trap-elute mode.…”
Section: Methodsmentioning
confidence: 99%
“…Ascites and serum samples were fractionated on QAE Sephadex A-25 (GE Healthcare Bio-Sciences AB, Sweden) strong anion exchange particles as described previously [8] . Briefly, 80 µL of sorbent was washed 2 times with 400 µL Wash buffer 1 (20 mM Tris (pH = 8.26)).…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…To desorb peptides from the surface of highly abundant proteins, we used the technique described earlier [7] , [8] . The eluates after anion exchange chromatography were incubated at 98 °C for 15 min.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation