2019
DOI: 10.1002/ccd.28635
|View full text |Cite
|
Sign up to set email alerts
|

Perceval sutureless valve migration treated by valve‐in‐valve with a CoreValve Evolut Pro

Abstract: In the last years, the use of sutureless devices in frail patients with severe aortic stenosis has increased thanks to their “easier and faster” technique of implantation in comparison to conventional surgery. Results from metanalysis show comparable outcomes in comparison to transcatheter aortic valve replacement (TAVR) in terms of mortality, stroke incidence, and rate of pace‐maker implantation. The incidence of para‐valvular leak (PVL) is even lower for sutureless devices than for TAVR. The few cases descri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…In addition, there is a report of 30 cases by Landes et al (22), as part of the VIVID International Registry (22), which may represent some of the single case reports, published in the literature overview given in Table 2. In the majority of cases, TAVR was performed in sutureless Perceval valves (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)20,21). There are only two case reports in which a TAVR procedure was described in a failed Intuity valve (5,19).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, there is a report of 30 cases by Landes et al (22), as part of the VIVID International Registry (22), which may represent some of the single case reports, published in the literature overview given in Table 2. In the majority of cases, TAVR was performed in sutureless Perceval valves (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)20,21). There are only two case reports in which a TAVR procedure was described in a failed Intuity valve (5,19).…”
Section: Discussionmentioning
confidence: 99%
“…To date, there are only case series that report on TAVR procedures in failed SV and RDV. To the best of our knowledge, a total number of 23 cases have been described so far (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21). This includes a previous publication by the authors (16).…”
Section: Literature Overview Of Tavr In Sv and Rdvmentioning