2022
DOI: 10.12659/ajcr.937063
|View full text |Cite
|
Sign up to set email alerts
|

Percutaneous Left Atrial Appendage Closure with the LAmbre Device Protected by a Cerebral Protection System in a 76-Year-Old Man with Persistent Left Atrial Appendage Thrombus

Abstract: Patient: Male, 76-year-old Final Diagnosis: Left atrial appendage thrombus despite optimal anticoagulation Symptoms: Palpitations Medication: — Clinical Procedure: Cryoballoon-based ablation • percutaneous left atrial appendage closure • transesophageal echocardiogram Specialty: Cardiology Objective: Unusual clinical course Background: Despite use of optimal oral anticoagulation regimens, left atria… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 36 publications
0
3
0
Order By: Relevance
“…The SL1 sheath was changed over a guidewire with the LAmbre sheath and the device landing zone diameter was measured by TEE and biplane angiography. The corresponding device was loaded on the delivery system and then advanced in the LA through the LAmbre sheath [ 25 ] Tan 2021 Watchman = 2 N/A N/A 1 2 TEE The Sentinel CPS device was placed using standard practices via the right radial artery with the two filters successfully deployed in the brachiocephalic and left common carotid artery. Using a 14 Fr double curve Watchman access sheath, a 30 mm Watchman device was successfully deployed at the ostium [ 26 ] Tsai 2023 Watchman = 2 Amulet Amplatzer = 8 10 10 9 10 TEE No-touch technique.…”
Section: Resultsmentioning
confidence: 99%
“…The SL1 sheath was changed over a guidewire with the LAmbre sheath and the device landing zone diameter was measured by TEE and biplane angiography. The corresponding device was loaded on the delivery system and then advanced in the LA through the LAmbre sheath [ 25 ] Tan 2021 Watchman = 2 N/A N/A 1 2 TEE The Sentinel CPS device was placed using standard practices via the right radial artery with the two filters successfully deployed in the brachiocephalic and left common carotid artery. Using a 14 Fr double curve Watchman access sheath, a 30 mm Watchman device was successfully deployed at the ostium [ 26 ] Tsai 2023 Watchman = 2 Amulet Amplatzer = 8 10 10 9 10 TEE No-touch technique.…”
Section: Resultsmentioning
confidence: 99%
“…As operators gained more experience over time, several authors published case reports on LAA occlusion in patients with thrombus present in the LAA. [12][13][14] In a previous study, we reported our own series of LAA occlusion procedures performed in patients with LAAT. 3,8,15 To the best of our knowledge, the current study represents the largest single-center registry focused on evaluating the effectiveness and safety of the LAAC procedure in patients with LAAT.…”
Section: Discussionmentioning
confidence: 99%
“…Thrombus formation in the LAA was traditionally considered to be a contraindication to percutaneous LAA closure. As operators gained more experience over time, several authors published case reports on LAA occlusion in patients with thrombus present in the LAA 12–14 . In a previous study, we reported our own series of LAA occlusion procedures performed in patients with LAAT 3,8,15 .…”
Section: Discussionmentioning
confidence: 99%