2006
DOI: 10.1373/clinchem.2006.070730
|View full text |Cite
|
Sign up to set email alerts
|

Performance and Clinical Utility of a Commercial von Willebrand Factor Collagen Binding Assay for Laboratory Diagnosis of von Willebrand Disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…Ten addressed diagnostic test accuracy for types 2A and 2B 59,85-93 and 6 for type 2M. [87][88][89][90]92,93 For types 2A and 2B, the sensitivity of VWF:CB/VWF:Ag was 0.90 (95% CI, 0.78-0.96) and specificity was 0.95 (95% CI, 0.89-0.98), vs a sensitivity of 0.90 (95% CI, 0.90-0.99) and specificity of 0.97 (95% CI, 0.94-0.99) for multimers. For type 2M VWD, the sensitivity of VWF:CB/VWF:Ag was 0.98 (95% CI, 0.96-1.00) with a specificity of 0.99 (95% CI, 0.98-1.00), vs a sensitivity of 0.86 (95% CI, 0.73-0.98) and a specificity of 0.97 (95% CI, 0.94-0.99) for multimers.…”
Section: Remarkmentioning
confidence: 99%
“…Ten addressed diagnostic test accuracy for types 2A and 2B 59,85-93 and 6 for type 2M. [87][88][89][90]92,93 For types 2A and 2B, the sensitivity of VWF:CB/VWF:Ag was 0.90 (95% CI, 0.78-0.96) and specificity was 0.95 (95% CI, 0.89-0.98), vs a sensitivity of 0.90 (95% CI, 0.90-0.99) and specificity of 0.97 (95% CI, 0.94-0.99) for multimers. For type 2M VWD, the sensitivity of VWF:CB/VWF:Ag was 0.98 (95% CI, 0.96-1.00) with a specificity of 0.99 (95% CI, 0.98-1.00), vs a sensitivity of 0.86 (95% CI, 0.73-0.98) and a specificity of 0.97 (95% CI, 0.94-0.99) for multimers.…”
Section: Remarkmentioning
confidence: 99%
“…These tests, summarized in Table 1, are prothrombin time, coagulation factor VIII activity (FVIII:C), vWF ristocetin cofactor activity assay (vWF:RCo), vWF antigen (vWF: Ag), vWF:RCo/Ag ratio as previously described, 8 vWF collagenbinding activity (vWF:CBA), vWF:CBA/Ag ratio, 9 and ADAMTS 13 (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13) activity (Genprobe, San Diego, CA) following the manufacturer's instructions.…”
Section: Coagulation Laboratory Testingmentioning
confidence: 99%
“…VWF:CB is a quantitative and qualitative assay which measures, typically by enzyme-linked immunosorbent assay (ELISA), the ability of VWF to bind collagen and is highly sensitive to the presence of high molecular weight VWF multimers. 6 Recently many reports have focused on the development of new tests for the diagnosis of VWD [6][7][8][9][10][11] and for monitoring the effects of treatments. 6,12 Indeed, patients with VWD are often treated with desmopressin (1-deamino-8-arginine vasopressin, DDAVP), a synthetic analog of the antidiuretic hormone vasopressin, which increases the plasma levels of factor VIII (FVIII) and VWF by 3 to 5-fold.…”
mentioning
confidence: 99%