2021
DOI: 10.1093/ofid/ofab243
|View full text |Cite
|
Sign up to set email alerts
|

Performance and Operational Evaluation of the Access Bio CareStart Rapid Antigen Test in a High-Throughput Drive-Through Community Testing Site in Massachusetts

Abstract: Background To facilitate deployment of point-of-care testing for SARS-CoV-2, we evaluated the Access Bio CareStart COVID-19 Antigen test in a high-throughput, drive-through, free community testing site using anterior nasal (AN) swab RT-PCR for clinical testing. Methods Consenting symptomatic and asymptomatic children (≤18 years) and adults received dual AN swabs. CareStart testing was performed with temperature/humidity monit… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(27 citation statements)
references
References 8 publications
1
26
0
Order By: Relevance
“…The supplementary information presents the sensitivities and specificities of antigen tests for SARS-CoV-2 from the included studies (see Figure S1). [16,18,22,23,[28][29][30]33]. The meta-analysis produced a pooled sensitivity of 0.76 (95% CI: 0.58-0.88) and a pooled specificity of 1.00 (95% CI: 0.99-1.00).…”
Section: Resultsmentioning
confidence: 93%
See 3 more Smart Citations
“…The supplementary information presents the sensitivities and specificities of antigen tests for SARS-CoV-2 from the included studies (see Figure S1). [16,18,22,23,[28][29][30]33]. The meta-analysis produced a pooled sensitivity of 0.76 (95% CI: 0.58-0.88) and a pooled specificity of 1.00 (95% CI: 0.99-1.00).…”
Section: Resultsmentioning
confidence: 93%
“…Eighteen studies with 34,865 participants were retrieved [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33]. Figure 1 depicts the process of the literature search, and Table 1 presents detailed characteristics of the studies.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Improper sampling and analysis of samples of these RA tests can influence the rate of false-positives and false-negatives 52,53 , and would therefore impact the required quarantine duration and testing frequency. Independently evaluated datasets on the testing of COVID-19 infections in the community were available for three of the RA tests 37,54 , enabling a comparison to the datasets that were provided from the EUA documentation. In two of the three comparisons (Sofia and CareStart), diagnostic sensitivity in independent analyses was lower than in ideal conditions.…”
Section: Empirical Validation Of Serial Ra Testing Within and Subsequent To Quarantine For Suppression Of Transmissionmentioning
confidence: 99%