Performance evaluation of a novel multi-pinhole collimator for dopamine transporter SPECT

Abstract: Purpose: There is a tradeoff between spatial resolution and count sensitivity in SPECT with conventional collimators. Multi-pinhole (MPH) collimator technology has potential for concurrent improvement of resolution and sensitivity in clinical SPECT of 'small' organs. This study evaluated a novel MPH collimator specifically designed for dopamine transporter (DAT) SPECT with a triple-head SPECT camera. Methods: Count sensitivity was measured with a 99m Tc point source placed on the lattice points of a 1cm grid c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 69 publications
0
12
0
Order By: Relevance
“…In all cases where image reconstruction was applicable, we used the same settings as for the patient scan, except in case of the spatial resolution results where lower reconstructed voxel size of 1.8 mm was applied. Measurements revealed increased TS pointsource of the triple head aperture system up to 1013 cps/MBq compared to the conventional LEHR sensitivity of 190 cps/MBq (49). In addition, this sensitivity gain is localized in the center of the FOV and decreasing towards the axial and radial edges, while for LEHR the sensitivity is relatively uniform throughout the entire FOV (49).…”
Section: Discussionmentioning
confidence: 91%
“…In all cases where image reconstruction was applicable, we used the same settings as for the patient scan, except in case of the spatial resolution results where lower reconstructed voxel size of 1.8 mm was applied. Measurements revealed increased TS pointsource of the triple head aperture system up to 1013 cps/MBq compared to the conventional LEHR sensitivity of 190 cps/MBq (49). In addition, this sensitivity gain is localized in the center of the FOV and decreasing towards the axial and radial edges, while for LEHR the sensitivity is relatively uniform throughout the entire FOV (49).…”
Section: Discussionmentioning
confidence: 91%
“…MPH projection data were reconstructed to transaxial SPECT images with the Monte Carlo photon simulation engine and iterative one-step-late maximum-a-posteriori expectation–maximization implemented in the camera software (30 iterations, 3 subsets). A more detailed description of the reconstruction method has been given previously [ 16 , 21 ]. Chang’s order zero method with linear broad-beam attenuation coefficient μ = 0.12/cm was used for post-reconstruction attenuation correction [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…The system count sensitivity profile of the triple-head SPECT system equipped with the novel general purpose brain imaging MPH collimator was measured as described previously by our group for a DAT-SPECT-specific MPH collimator [ 16 ]. In brief, a point source (5–10 MBq 99m Tc in about 5 µl in an Eppendorf tube) was placed on the lattice points of a 1 cm grid covering the whole field of view.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In particular, novel large-field cadmium–zinc–telluride and the use of a 360° detector ring may combine high-quality images, and high-speed recording increased by twofold in clinical conditions [ 201 , 202 ]. Improved contrast may also be achieved using multi-pinhole (MPH) collimators for DAT-SPECT, close to striatal delineation with PET [ 203 ]. As demonstrated before, interpretation has greatly improved using normative atlas and validation of innovative segmentation methods [ 204 ], and may greatly benefit from the use of machine learning in particular for differential diagnosis and prediction of individual prognosis for precision-medicine and use in neuroprotection trials.…”
Section: New Perspectives For Tracer Development and Technical Advancesmentioning