Performance evaluation of adding Helical-screw Tape Inserts in Parabolic Solar Trough Collectors as a Source of Cleaner Energy Production

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 45 publications
(7 citation statements)
references
References 38 publications
0
7
0
Order By: Relevance
“…This term describes the enhancement of the Nusselt number over the enhancement of the friction factor, as shown in Equation ( 6). More heat is transmitted over the channel when the performance factor is higher than the corresponding pressure drop represented by the friction factor: [39] η…”
Section: Data Reductionmentioning
confidence: 99%
See 2 more Smart Citations
“…This term describes the enhancement of the Nusselt number over the enhancement of the friction factor, as shown in Equation ( 6). More heat is transmitted over the channel when the performance factor is higher than the corresponding pressure drop represented by the friction factor: [39] η…”
Section: Data Reductionmentioning
confidence: 99%
“…This term describes the enhancement of the Nusselt number over the enhancement of the friction factor, as shown in Equation (6). More heat is transmitted over the channel when the performance factor is higher than the corresponding pressure drop represented by the friction factor: [ 39 ] η=Nufalse/Nuo(ffalse/fo)1false/3$$\eta = \frac{N u / N u_{o}}{\left(\left(\right. f / f_{\text{o}} \left.\right)\right)^{1 / 3}}$$where “ f o ” and “ Nu o ” are the values computed from the base case of SAHs.…”
Section: Data Reductionmentioning
confidence: 99%
See 1 more Smart Citation
“…They had varied the angle of attacks and studied its effect on pressure co-efficient, lift and drag. In their study, A. Raheem et al [14] investigated the impact of helical screw inserts on the efficiency of the absorber tube in parabolic trough collectors. The use of helical screw inserts inside the absorber tube of the collector holds the capacity to augment its efficiency.…”
Section: Introductionmentioning
confidence: 99%
“…Thermal efficiency, as well as Nusselt number, were improved by around 1.2% and 12%, respectively, by increasing copper concentration in terms of volume in water, according to the study. Raheem et al 32 investigated the hydraulic and thermal influence of putting a helical‐screw structured tape in a normal tube for Reynolds numbers ranging from 4400 to 7000. PEC and Nusselt numbers improved by 23% and 53%, respectively, according to the study.…”
Section: Introductionmentioning
confidence: 99%