Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…4, Table 1, Table 2, and Table 3. Film dosimetry used in this investigation followed a protocol that yielded a dose uncertainty below 3.0 % [39].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…4, Table 1, Table 2, and Table 3. Film dosimetry used in this investigation followed a protocol that yielded a dose uncertainty below 3.0 % [39].…”
Section: Resultsmentioning
confidence: 99%
“…Irradiating lms parallel to the beam, in the coronal plane, within solid water blocks of dimensions 20´30 ´n cm 3 would minimise this issue; however, these were not available during this investigation. Film data, while noisy compared to Geant4 and Monaco TPS PDD curves, demonstrate that lm can be useful to experimentally generate a continuous depth dose pro le, whereas the MOSkin™ is point dose speci c. The lm data demonstrates the sensitivity of air gaps on lm dosimetry in the MR-linac despite following a protocol that yields an uncertainty below 3.0 % [39].…”
Section: Discussionmentioning
confidence: 98%
“…Irradiating films parallel to the beam, in the coronal plane, within solid water blocks of dimensions 20 × 30 × n cm 3 would minimise this issue; however, these were not available during this investigation. The continuous depth dose film data demonstrates the sensitivity of air gaps on film dosimetry in the MR-linac despite following a protocol that yields an uncertainty below 3.0% [ 47 ]. Perpendicular film irradiation has the potential to address the overestimation of surface dose obtained by irradiating the film in a parallel orientation.…”
Section: Discussionmentioning
confidence: 99%
“…Due to scan resolution, film entry and exit measurement points begin at a depth of 0.34 mm within the solid water phantom. Film dosimetry used in this investigation followed a protocol that yielded a dose uncertainty below 3.0% [ 47 ].…”
Section: Methodsmentioning
confidence: 99%
“…Films were scanned as previously for calibration, and lateral scanner variations were corrected using a MAT-LAB script. 42 Profiles across the ESE distribution in the x-direction were created in FilmQA™ Pro using a 25.0 × 0.3 cm 2 ROI. Along each profile, the dose corresponding to the position of the point-dose dosimeter measurements was recorded.…”
Section: Measurementsmentioning
confidence: 99%