2014
DOI: 10.1016/j.cryogenics.2014.06.012
|View full text |Cite
|
Sign up to set email alerts
|

Performance evaluation of heat exchanger for mixed refrigerant J–T cryocooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
8
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 19 publications
1
8
0
Order By: Relevance
“…This explains the reason of these differences. A similar observation was reported by Ardhapurkar et al [14], in their calculation (theoretical and experimental) of overall heat transfer coefficients with modified Granryd correlation on the boiling side and Cavallini and Zecchin [17] correlation for condensation. The deviations reported by them between the experimental and theoretical values of heat transfer coefficients were in the range of 3-18.7%.…”
Section: Resultssupporting
confidence: 73%
See 2 more Smart Citations
“…This explains the reason of these differences. A similar observation was reported by Ardhapurkar et al [14], in their calculation (theoretical and experimental) of overall heat transfer coefficients with modified Granryd correlation on the boiling side and Cavallini and Zecchin [17] correlation for condensation. The deviations reported by them between the experimental and theoretical values of heat transfer coefficients were in the range of 3-18.7%.…”
Section: Resultssupporting
confidence: 73%
“…Based on the conclusions drawn by Ardhapurkar et al [14], the correlation of Cavallini and Zecchin [17] is employed for calculating the condensation heat transfer coefficients. Cavallini and Zecchin [17] correlation for condensation is a modified form of the well-known Dittus-Boelter correlation.…”
Section: Heat Transfer Correlationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experimental two-phase frictional pressure drop data are compared with 15 existing correlations which are used for flows through both macro and mini/micro channels. The average absolute deviations (AAD) for the predicted results are calculated using equation (6), in order to find applicability of the correlations. 1 100…”
Section: Resultsmentioning
confidence: 99%
“…These studies are mainly related to the optimization of mixtures used and the overall performance of the refrigeration systems. However, little work [5][6][7] is done on the performance analysis of the recuperative heat exchanger used in the MR J-T cryocooler, even though it plays a crucial role in its efficient operation. This is mainly due to the lack of the experimental data available, related to flow boiling/condensation heat transfer and pressure drop of mixed refrigerants at cryogenic temperatures.…”
mentioning
confidence: 99%