Abstract:The study was undertaken to determine the performance of submersible pump and mono-block centrifugal pump to develop characteristic curves of and its operating conditions. The results revealed that submersible pump the maximum all over pump set efficiency was found 54.98 % at working head 40.43 m, discharge equal to 24.10 lps, WHP 12.99 and input HP 23.63, it was operating point of pump. More than 50 % efficiency can be achieved with discharge capacity varied between 24.10 to 17.89 lps. While Mono-block pump t… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.