2008
DOI: 10.1080/10739140802448275
|View full text |Cite
|
Sign up to set email alerts
|

Performance of a Dual Sample Introduction System with Conventional Concentric Nebulizers for Simultaneous Determination of Hydride and Non-Hydride Forming Elements by ICP-OES

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…Commercially available spectrometers were applied for ICP-OES and the Ar plasma in these instruments was typically axially 1,5,7,8,16,17,20,21,24,26,30,[33][34][35]40,41,[43][44][45][46][47][48][49][50][51][52][53][54] viewed. Older apparatus with radial 2,6,9,[11][12][13][14]25,27,28,32,[36][37][38][39]42,[55][56][57][58][59][60][61][62] viewing of Ar-ICP were ...…”
Section: Reaction/separation Manifoldsmentioning
confidence: 99%
See 2 more Smart Citations
“…Commercially available spectrometers were applied for ICP-OES and the Ar plasma in these instruments was typically axially 1,5,7,8,16,17,20,21,24,26,30,[33][34][35]40,41,[43][44][45][46][47][48][49][50][51][52][53][54] viewed. Older apparatus with radial 2,6,9,[11][12][13][14]25,27,28,32,[36][37][38][39]42,[55][56][57][58][59][60][61][62] viewing of Ar-ICP were ...…”
Section: Reaction/separation Manifoldsmentioning
confidence: 99%
“…Modified cyclonic spray chambers with two entrance ports for mounting pneumatic nebulizers were applied to achieve dual sample introduction as well. [11][12][13] In these systems, acidified sample and alkaline THB solutions were nebulized into spray chambers using two Meinhard-type concentric 11,12 or high efficiency nebulizers. 13 The angle between arms of nebulizers that maintained the best analytical performance for hydride and non-hydride forming elements was established to be 45 .…”
Section: Simultaneous Hg and Pnmentioning
confidence: 99%
See 1 more Smart Citation
“…However, no signal for In was obtained in HG mode although Indium can form volatile hydrides. It is also possible to combine vapor generation and liquid nebulization with ICP-OES and ICP-MS techniques using a commercial or house-made multi-mode sample introduction systems (MSIS) [12][13][14][15][16][17]. Our research group [18] reported on the usage of this kind of system for internal standardization in the determination of mercury in natural waters with cold vapor (CV) ICP-MS. Pt, Pd, Tl and Bi were used to correct the variation in mercury signals.…”
Section: Introductionmentioning
confidence: 97%
“…Selenium, introduced as hydride, was determined simultaneously with the other non-hydride-forming elements using the commercial multi-mode sample introduction system (MSIS) which was also used by Wiltsche et al 7 for the multielemental analysis in high alloy steels and nickel alloys using axially viewed hydride generation ICP OES. On the other hand, Benzo et al 8 employed a system which consists of two commercial conventional concentric nebulizers coupled to a modified cyclonic chamber for the determination of As, Be, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Pb, Se, Sb, Sr, V and Zn. The system provided a convenient means of determining elements, either by nebulisation or hydride generation or simultaneously in the same device without suffering losses during the time.…”
Section: Introductionmentioning
confidence: 99%