Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in children

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
55
2
5

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 87 publications
(63 citation statements)
references
References 8 publications
1
55
2
5
Order By: Relevance
“…Although our PPV is lower than has been reported in other studies, 4,6 these studies were performed in a population with a higher disease prevalence, which artificially raises the PPV from that of the general population. Our referral rate (27%) is both greater and less than that found in other reported programs.…”
Section: Discussioncontrasting
confidence: 79%
See 1 more Smart Citation
“…Although our PPV is lower than has been reported in other studies, 4,6 these studies were performed in a population with a higher disease prevalence, which artificially raises the PPV from that of the general population. Our referral rate (27%) is both greater and less than that found in other reported programs.…”
Section: Discussioncontrasting
confidence: 79%
“…The Plusoptix has been shown to be sensitive in detection of amblyopia risk factors in young children. 4,[6][7][8] The Plusoptix SO8 was used initially, followed by the model upgrade SO9. Modifications to the referral criteria were made according to screener-specific recommendations to maximize sensitivity and specificity in detection of refractive errors according to American Association for Pediatric Ophthalmology and Strabismus guidelines: Arthur modification 1 (anisometropia ≥ 1.5 D, hyperopia ≥ 3.5 D, myopia ≥ 3.0 D, astigmatism ≥ 2.0, anisocoria ≥ 1 mm).…”
Section: Screening Processmentioning
confidence: 99%
“…21 In two different studies of Matta et al, Plusoptix S04 was also reported as an effective screening tool, because it was found a useful tool for the detection of amblyopia risk factors and showed a high sensitivity of 98.9% and specificity of 96.1%. 12,22 Paff et al evaluated the performance of a hand held autorefractor and PlusoptiX S08 in measuring refractive errors as a vision screener by comparing them with cycloplegic retinoscopy (CR) of 200 children. When compared to CR, the PlusoptiX S08 showed a mean difference of -1.13 ± 1.25 D for spherical equivalent (SE) and -0.23±0.53 D for the cylinder; after cycloplegia -2.11±1.64 D for SE and -0.06±0.47 D for the cylinder were measured.…”
mentioning
confidence: 99%
“…El instrumento PlusoptiX puede ser usado para facilitar tamizajes, aunque presente dificultades en condiciones de alta iluminación. Investigaciones anteriores han encontrado una sensibilidad y especificidad más alta, aunque en poblaciones en las que se sospecha que los ojos no eran, en su mayoría, de iris oscuro (Matta et al, 2008;Singman et al 2013). La evaluación adicional en condiciones más controladas debería mirar el efecto del color del iris en su exactitud.…”
Section: Discussionunclassified
“…Varios estudios han evaluado los instrumentos PlusoptiX y han encontrado sensibilidad y especificidad generalmente alta con el PlusoptiX (Matta et al, 2008;Singman et al, 2013). Sin embargo, estos estudios se han realizado en clínicas oftalmológicas pediátricas, lo cual indica que se efectuaron desde circunstancias controladas y con poblaciones de alta prevalencia de factores de riesgo de ambliopía.…”
Section: Figura 1 Instrumento Portátil Plusoptixunclassified