2018
DOI: 10.1109/jphot.2018.2828419
|View full text |Cite
|
Sign up to set email alerts
|

Performance Review of Multiple Reference Versus Time Domain Optical Coherence Tomography

Abstract: We present a detailed characterization of noise sources in multiple reference optical coherence tomography (MR-OCT) compared to time-domain OCT (TD-OCT). The noise characteristics were modeled based on the TD-OCT noise model and modified for MR-OCT and confirmed with measurements. The MR-OCT sensitivity characteristics are significantly affected by the reflection from the partial mirror, which also introduces a natural attenuation in the reference arm, partially matching the reflectivity intensity profile of h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…To characterize the coherence envelope and localize its peak, a few measurements per half-period of the fringe pattern are needed. Measurement parallelization with polarizationmultiplexed phase shifting [65], multiple reference arm reflection planes [66] or off-axis holographic setups [67] are possible. Increasing object depth within the FOV leads to detrimental speckles and defocus-induced cross talk.…”
Section: Coherence Scanning Interferometrymentioning
confidence: 99%
“…To characterize the coherence envelope and localize its peak, a few measurements per half-period of the fringe pattern are needed. Measurement parallelization with polarizationmultiplexed phase shifting [65], multiple reference arm reflection planes [66] or off-axis holographic setups [67] are possible. Increasing object depth within the FOV leads to detrimental speckles and defocus-induced cross talk.…”
Section: Coherence Scanning Interferometrymentioning
confidence: 99%
“…If the light source has a Gaussian power distribution then the function G(δl) represents the Gaussian envelope of the interference amplitude along δl. The angular frequency is ω = 2πf and ϕ is the initial phase of the frequency content of the interference [15], [28]. Compared to TD-OCT, MR-OCT has an additional partial mirror (PM) in front of the scanning reference mirror.…”
Section: A Multiple Reference Optical Coherence Tomographymentioning
confidence: 99%
“…to incorporate the sum of reference and sample arm powers (P r and P s ) for each order N [15]. The component P PM0 is the power of the first reflection from the partial mirror back to the beam splitter and the detector describing most of the noncoherent DC background on the detector signal.…”
Section: A Multiple Reference Optical Coherence Tomographymentioning
confidence: 99%
See 1 more Smart Citation
“…A typical example of the interferometric use of lowcoherence sources is the Optical Coherence Tomography i.e. OCT [6], [7]. Such technique is based on the light generated by a superluminescent diode (SLD) that is guided by a single mode fiber on living tissues (typically ocular tissues); light back-scattered from the different layers is collected and the signal resulting from the interference with a reference beam is detected using high-sensitivity and low-noise detectors, allowing reconstructing in-vivo three-dimensional map of tissues.…”
Section: Introductionmentioning
confidence: 99%