Abstract:Rat hearts have been preserved for 24 hours using four different preservation solutions. The results suggest that the best preservation fluid is Tyrode's solution with Ficoll 5 per cent. A comparison of simple cooling of the heart and perfusion, either continuous or intermittent, has shown that intermittent perfusion of the heart for 2 minutes every 6 hours gives the highest rate of 24-hour preservation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.