2019
DOI: 10.1016/j.jmbbm.2018.12.035
|View full text |Cite
|
Sign up to set email alerts
|

“Peroperative estimation of bone quality and primary dental implant stability”

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(25 citation statements)
references
References 51 publications
0
25
0
Order By: Relevance
“…Albeit bone surrogates do not fully replicate the mechanical properties of human bone, they are intended to provide consistent and uniform material with properties in the range of human cancellous bone [25]. The second in vitro study was performed in controlled laboratory conditions using trabecular bone samples from bovine tibia plateau [7]. The volume fraction of the trabecular bone across anatomic sites ranged between 14% and 31%, which would correspond to trabecular core found in posterior maxilla and anterior mandible, respectively [26].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Albeit bone surrogates do not fully replicate the mechanical properties of human bone, they are intended to provide consistent and uniform material with properties in the range of human cancellous bone [25]. The second in vitro study was performed in controlled laboratory conditions using trabecular bone samples from bovine tibia plateau [7]. The volume fraction of the trabecular bone across anatomic sites ranged between 14% and 31%, which would correspond to trabecular core found in posterior maxilla and anterior mandible, respectively [26].…”
Section: Discussionmentioning
confidence: 99%
“…Samples were then segmented (threshold: 414 mgHA/ccm) to quantify the bone volume fraction (BV/TV) of each specimen. Afterwards, all samples were embedded into polymethylmethacrylate (PMMA) as previously described [7]. Bovine bone cylinders were frozen at −21 • between uses.…”
Section: In Vitro Bovine Trabecular Bonementioning
confidence: 99%
See 2 more Smart Citations
“…Primary implant stability played a key role in evaluating the success of dental implant surgery. It mainly maintained a low micromovement during the early healing time of the dental implant and promoted the combination of bone and the surface of the implant Open Access Journal [20,21]. Therefore, the acquirement of primary implant stability during the implant placement was crucially important.…”
Section: Sci Forschenmentioning
confidence: 99%